In situ leg length measurement technique in hip arthroplasty.

نویسنده

  • William B Kurtz
چکیده

In situ femoral preparation refers to implanting a femoral component before the femoral neck osteotomy and without dislocating the hip joint, which allows the implanted femoral component to be used to measure leg length and offset. One hundred hip arthroplasty surgeries among 93 patients were compared with a control group of 15 patients. A modular neck femoral component was implanted in a technique similar to implanting a femoral nail. The differences between the in situ measurements and the preoperative and postoperative radiograph measurements averaged -0.1 mm for leg length (r = 0.89) and -0.37 mm for offset (r = 0.57). In situ leg length measurement allows accurate measurement of leg length and offset and guides surgeons in selecting appropriate modular components to attain a near anatomical hip arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty

Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...

متن کامل

The impact of leg length discrepancy on clinical outcome of total hip arthroplasty: comparison of four measurement methods.

In a single-surgeon series of 119 patients with unilateral primary uncemented total hip arthroplasty, four leg-length discrepancy measurement methods (absolute, relative, trochanteric, standardized-trochanteric) were analyzed for their impact on WOMAC score, Oxford Hip Score and self-perceived leg-length discrepancy. After adjustment for age, gender and BMI, postoperative WOMAC scores correlate...

متن کامل

Evaluation of a new leg length measurement algorithm in hip arthroplasty.

Leg length inequality after hip arthroplasty is a major source of patient dissatisfaction and dysfunction. Despite numerous reported methods to intraoperatively determine leg length change, it remains a challenge. We developed a reliable and reproducible method to measure leg length change using surgical navigation. The method measures the change in position of the femur relative to the pelvis ...

متن کامل

Accurate Leg Length Measurement in Total Hip Arthroplasty: A Comparison of Computer Navigation and a Simple Manual Measurement Device

BACKGROUND Several studies have shown that better placement of the acetabular cup and femoral stem can be achieved in total hip arthroplasty (THA) by using the computer navigation system rather than the free-hand alignment methods. However, there have been no comparisons of the relevant clinical advantages in using the computer navigation as opposed to the manual intraoperative measurement devi...

متن کامل

Assessing reproducibility for radiographic measurement of leg length inequality after total hip replacement.

Leg length inequality (LLI) as a result of total hip replacement can cause considerable morbidity. Although LLI was described when the technique was popularised in the 1960s, it remains a significant challenge to arthroplasty surgeons. This study reviews the established practice for the measurement of LLI on plain antero-posterior radiograph, and compares these techniques to two methods used lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2012