A new laboratory polymerizing apparatus equipped with halogen and metal halide light sources.
نویسندگان
چکیده
We developed a new laboratory polymerizing unit (Twinkle MIII: M3) equipped with different light sources (a metal halide and two halogen lamps) that could illuminate independently. This study introduced the structure of the curing unit and examined the curing depth of a representative indirect composite (Artglass). The composite material was cured with the following modes: 1) M3 - halogen only; 2) M3 - metal halide only; 3) M3 - both halogen and metal halide (HM); 4) conventional xenon; and 5) preliminary halogen. The results obtained from analysis of variances and post-hoc tests revealed that curing depth was affected significantly (p < 0.05) by both exposure mode and time, and that HM mode exhibited the most favorable curing performance (p < 0.05) among the curing units and polymerization modes. In conclusion, the M3 unit was found to be well suited to polymerizing the composite material tested.
منابع مشابه
Depth of cure and hardness of an indirect composite polymerized with three laboratory curing units.
This study determined the hardness and curing depth of a light-activated indirect composite polymerized with three laboratory light-polymerizing units for the purpose of comparing the curing performance of the three units. A light-activated composite material for indirect application (Vita Zeta) was polymerized with three light-polymerizing units equipped with the following light sources: 1) on...
متن کاملUse of FT-Raman Spectroscopy to Determine the Degree of Polymerization of Dental Composite Resin Cured with a New Light Source
OBJECTIVES To use the FT-Raman spectroscopy for evaluation the degree of polymerization of dental composite as a result of photo curing with a new light source in comparison to the conventional halogen light. MATERIALS AND METHODS In this study a new light source, based on a metal-halide lamp (TOPSPOT G12) was developed at NRC-Egypt for curing dental composites. Two groups of 108 composite sa...
متن کاملEffect of metal halide light source on hardness, water sorption and solubility of indirect composite material.
This study evaluates the effects of a metal halide light source on the post-polymerization properties of the Sinfony indirect composite material. Two polymerization systems were employed: the Hyper LII system, comprising a metal halide polymerization unit, and the Visio system, comprising two proprietary units designed for polymerizing the Sinfony composite. The composite material was polymeriz...
متن کاملProperties of an indirect composite material polymerized with two different laboratory polymerizing systems.
The purpose of the current study was to evaluate the performance of two laboratory light polymerization systems used to polymerize an indirect composite (Sinfony). A two-step polymerization system (Visio-Alfa and Beta) and a halogen-metal halide unit (Twinkle MIII) were assessed. The composite was polymerized either with the Visio units or with the MIII unit for different exposure periods. Knoo...
متن کاملInfluence of laboratory light sources on the wear characteristics of indirect composites.
The purpose of the current study was to evaluate the influence of light sources on the mechanical properties and wear characteristics of indirect composite materials. The two composite materials used were Estenia C&B and Epricord. The three laboratory polymerization units used, of which the wavelength range was 400-500 nm, were Hyper LII (two metal halide lamps of 4.82 mW/cm(2)), α-Light II (on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Dental materials journal
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2005