Kinetic determination of hexosaminidases for Tay-Sachs heterozygote screening.

نویسندگان

  • L Zinterhofer
  • G Schuttringer
چکیده

We describe a method for continuous kinetic measurement of hexosaminidase activity, and have applied it to detection of heterozygotes for Tay-Sachs gene. In contrast to existing single-point methods, a ph of 4.5, which is optimal for hexosaminidase activity on the substrate (4-methylumbelliferyl-N-acetyl-beta-d-glucosaminide) is maintained while the increase in fluorescence produced by 4-methylumbelliferone, the reaction product, is being determined. Under the conditions described the reaction follows zero-order kinetics, and activity is linearly related to serum dilution. There is a fairly narrow but practicable range of optimal substrate concentration. The presence of substrate in concentrations exceeding 1 mmol/liter results in progressive quenching of fluorescence and a decrease in apparent enzyme activity. The procedure is standardized with 4-methylumbelliferone in a solution of the substrate. This method is adaptable to use with automated multiple-point discrete-sample devices and especially with the fluorometric kinetic analyzers now being developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated assay of hexosaminidases in serum.

In serum there are two classes of hexosaminidase. One of these is heat-labile and is inactive in children with Tay-Sachs disease. Serum from heterozygotes for Tay-Sachs disease has half the normal activity of the heat-labile enzyme. The heat-labile enzyme can be inactivated by heating serum diluted in buffer for 5 mm at 60 #{176}C. We have used this property to develop a reliable, fully automat...

متن کامل

Screening for carriers of Tay-Sachs disease in the ultraorthodox Ashkenazi Jewish community in Israel.

A screening program for the detection of Tay-Sachs disease (TSD) carriers in the ultra Orthodox community of Ashkenazi Jews has operated in Israel since 1986. The purpose of this program is the prevention of marriages of 2 heterozygotes. The screened individuals are mostly couples in the engagement process or students in religious high schools. Two mandatory requirements guide this program. Fir...

متن کامل

Automated determination of serum hexosaminidase A by pH inactivation for detection of Tay-Sachs disease heterozygotes.

We have automated a manual test for detection of heterozygotes of Tay-Sachs disease by assay of hexosaminidase A in serum, based on pH inactivation [C/in. Chim. Acta 43, 417 (1973)]. The same manifold is used both for the total hexosaminidase and pH-inactivation (hexosaminidase B) procedures. Automation expedites mass screening of the Ashkenazi Jewish population for carriers of the TaySachs gen...

متن کامل

Tay-Sachs screening in the Jewish Ashkenazi population: DNA testing is the preferred procedure.

A unique screening program for the identification of Tay-Sachs Disease (TSD) heterozygotes has been performed in the tradi- tional Orthodox Ashkenazi Jewish (AJ) community since 1983. In recent years the program has utilized the biochemical assay for the determination of hexosaminidase A levels by the heat inactivation technique as well as by direct DNA analysis. The three mutations which were ...

متن کامل

Tay-Sachs disease heterozygote detection: use of a centrifugal analyser for automation of hexosaminidase assays with two different artificial substrates.

An assay for measuring hexosaminidase A in serum and leucocytes is described in which a centrifugal analyser is used for automation of the enzyme assays after manual heat inactivation. The assay was used in a screening programme to identify heterozygotes for Tay-Sachs disease in Ashkenazi Jewish subjects in the UK. The first results from this programme indicate a carrier frequency of 1 in 27. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 1976