Direct comparison of the FibroScan XL and M probes for assessment of liver fibrosis in obese and nonobese patients

نویسندگان

  • Esteban Durango
  • Christian Dietrich
  • Helmut Karl Seitz
  • Cornelia Ursula Kunz
  • Gilles T Pomier-Layrargues
  • Andres Duarte-Rojo
  • Melanie Beaton
  • Magdy Elkhashab
  • Robert P Myers
  • Sebastian Mueller
چکیده

BACKGROUND A novel Fibroscan XL probe has recently been introduced and validated for obese patients, and has a diagnostic accuracy comparable with that of the standard M probe. The aim of this study was to analyze and understand the differences between these two probes in nonobese patients, to identify underlying causes for these differences, and to develop a practical algorithm to translate results for the XL probe to those for the M probe. METHODS AND RESULTS Both probes were directly compared first in copolymer phantoms of varying stiffness (4.8, 11, and 40 kPa) and then in 371 obese and nonobese patients (body mass index, range 17.2-72.4) from German (n = 129) and Canadian (n = 242) centers. Liver stiffness values for both probes correlated better in phantoms than in patients (r = 0.98 versus 0.82, P < 0.001). Significantly more patients could be measured successfully using the XL probe than the M probe (98.4% versus 85.2%, respectively, P < 0.001) while the M probe produced a smaller interquartile range (21% versus 32%). Failure of the M probe to measure liver stiffness was not only observed in patients with a high body mass index and long skin-liver capsule distance but also in some nonobese patients (n = 10) due to quenching of the signal from subcutaneous fat tissue. In contrast with the phantoms, the XL probe consistently produced approximately 20% lower liver stiffness values in humans compared with the M probe. A long skin-liver capsule distance and a high degree of steatosis were responsible for this discordance. Adjustment of cutoff values for the XL probe (<5.5, 5.5-7, 7-10, and >10 kPa for F0, F1-2, F3, and F4 fibrosis, respectively) significantly improved agreement between the two probes from r = 0.655 to 0.679. CONCLUSION Liver stiffness can be measured in significantly more obese and nonobese patients using the XL probe than the M probe. However, the XL probe is less accurate and adjusted cutoff values are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Comparison between the M and XL probes for liver fibrosis assessment by transient elastography.

OBJECTIVE Liver stiffness measurement (LSM) using Transient Elastography (TE) for liver fibrosis assessment is difficult to be performed in obese and overweight patients by standard M probe, thus the XL probe was developed. The aim of our paper was to assess the usefulness of the XL probe in daily clinical practice. MATERIAL AND METHOD Our study included 216 patients (mean BMI 30.1+/-4.1 kg/m...

متن کامل

Non-invasive assessment of liver fibrosis with transient elastography (FibroScan®): applying the cut-offs of M probe to XL probe.

UNLABELLED BACKGROUND AND RATIONALE FOR THE STUDY: Limited studies have aimed to define the cut-offs of XL probe (XL cut-offs) for different stages of liver fibrosis, whereas those of M probe (M cut-offs) may not be applicable to XL probe. We aimed to derive appropriate XL cut-offs in overweight patients. Patients with liver stiffness measurement (LSM) by both probes were recruited. XL cut-offs...

متن کامل

Update of liver fibrosis and steatosis with transient elastography (Fibroscan)

BACKGROUND Assessment of liver fibrosis and steatosis is now almost indispensable in most of the chronic liver diseases in order to determine prognosis and need for treatment, and to monitor disease progression and response to treatment. Liver biopsy is limited by its invasiveness and patient acceptability. Transient elastography (TE; Fibroscan) is a non-invasive tool with satisfactory accuracy...

متن کامل

Assessment of hepatic fibrosis by transient elastography in rheumatoid arthritis patients receiving methotrexate

Background and Aim: Methotrexate (MTX) is commonly used in the treatment of diseases such as rheumatoid arthritis (RA) but, its hepatotoxicity potential, always has been a major concern. The aim of this study is to determine the rate of liver fibrosis by transient elastography (TE) method and its relationship with cumulative dose of MTX and duration of treatment, in rheumatoid arthritis patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013