BACKGROUND AND PURPOSE Despite the fact that there have been some reports on poor performance, titanium femoral stems intended for cemented fixation are still used at some centers in Europe. In this population-based registry study, we examined the results of the most frequently used cemented titanium stem in Norway. PATIENTS AND METHODS 11,876 cases implanted with the cemented Titan stem were identified for the period 1987-2008. Hybrid arthroplasties were excluded, leaving 10,108 cases for this study. Stem survival and the influence of age, sex, stem offset and size, and femoral head size were evaluated using Cox regression analyses. Questionnaires were sent to the hospitals to determine the surgical technique used. RESULTS Male sex, high stem offset, and small stem size were found to be risk factors for stem revision, (adjusted RR = 2.5 (1.9-3.4), 3.3 (2.3-4.8), and 2.2 (1.4-3.5), respectively). Patients operated in the period 2001-2008 had an adjusted relative risk (RR) of 4.7 (95% CI: 3.0-7.4) for stem revision due to aseptic stem loosening compared to the period 1996-2000. Changes in broaching technique and cementing technique coincided with deterioration of the results in some hospitals. INTERPRETATION The increased use of small stem sizes and high-offset stems could only explain the deterioration of results to a certain degree since the year 2000. The influence of discrete changes in surgical technique over time could not be fully evaluated in this registry study. We suggest that this cemented titanium stem should be abandoned. The results of similar implants should be carefully evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants

BACKGROUND There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants. METHODS This paper r...

متن کامل

Medium-term Outcome of Cemented Titanium Stems

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the fiveto ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision...

متن کامل

In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study

The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral graft of porous titanium particles in terms of graft thickness, cement thickness, and cement penetrat...

متن کامل

Long-term survival of a cemented titanium-aluminium-vanadium alloy straight-stem femoral component.

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean f...

متن کامل

Corrosion of cemented titanium femoral stems.

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem ebonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pa...