Domestic microwave versus conventional tissue processing: a quantitative and qualitative analysis.
نویسندگان
چکیده
BACKGROUND Microwave irradiation has been tried as a replacement for the conventional tissue processing technique in histopathology laboratories for quite some time. Studies have shown that Domestic Microwave Tissue Processing (DMWTP) provides a faster delivery of the tissue sections with a morphology which is similar to that which is seen Conventional Tissue Processing (CTP). But many laboratories still confine the domestic microwave tissue processing method only to the handle selected specimens, for which urgent reports are needed. One of the probable reasons is that, understanding about the number of tissue sections which can be processed using a microwave oven at a time, with the appropriate quality, still remains unclear. AIM The aim of this study was to quantitatively analyze the optimum number of samples that a domestic microwave could process at a time, as well as to qualitatively analyze the morphological outcome of those tissue sections with that of conventional processing. MATERIALS AND METHODS This study was approved by the research and ethical committee of Sree Balaji Medical College and Hospital. A total of 135 paired tissue sections were included in the study. Ten tissue sections (which are mentioned hereafter as A10) were processed in a domestic microwave and their paired 10 tissues were processed by a conventional method. Subsequently, the number of tissues which was to be processed was increased to B15, C20, D25, E30 and F35, after ascertaining that the morphological qualities of the previously processed tissue sections were satisfactory. Sections of 4 μm thickness were taken and they were stained by the Haematoxylin and Eosin method. The slides of the tissues which were processed by the microwave method and the conventional method were randomly numbered, for a blind study, which were independently evaluated by two observers. The qualities of slides were assessed, based on 4 parameters: the cytoplasmic details, the nuclear details, the tissue architecture and the staining characteristics. The statistical analysis was done by using SPSS 15.0. RESULTS The morphological outcomes (quality) of the DMWTPs were comparable to that of the CTPs, when the sample load (quantity) in the microwave oven was up to 25 samples. CONCLUSION Domestic microwave processing can be effectively used in laboratories with a maximum sample size of 25 samples per load. This has the advantage of being rapid, with its morphological quality being identical to that of conventional processing.
منابع مشابه
Comparison of Prostatic Tissue Processed by Microwave and Conventional Technique Using Morphometry
Background and Objectives:Rapid processing of histopathological specimens and decreased turnaround time is important to fulfill the needs of clinicians treating sick patients, so the present study was conducted to compare the time taken and quality of sections in processing of prostatic tissue by rapid microwave and conventional techniques using morphometry. Methods: Four to five mm thick p...
متن کاملMicrowave : Useful in kitchen / Pathology Lab ?
Conventional tissue processing of histologic specimens has been carried out in the same manner for many years. It is a time-consuming process involving batch production, resulting in a 1-day delay of the diagnosis. Microwave-assisted tissue processing enables a continuous high flow of histologic specimens through the processor with a processing time of as low as 1 h. In this article we review t...
متن کاملMixed Qualitative/Quantitative Dynamic Simulation of Processing Systems
In this article the methodology proposed by Li and Wang for mixed qualitative and quantitative modeling and simulation of temporal behavior of processing unit is reexamined and extended to more complex case. The main issue of their approach considers the multivariate statistics of principal component analysis (PCA), along with clustered fuzzy digraphs and reasoning. The PCA and fuz...
متن کاملQualitative versus Quantitative Evaluation of Scientists' Impact: A Medical Toxicology Tale
Evaluation of scientists working in a specific area of science is necessary, as they may strive for same limited resources, grants and academic promotions. One of the most common and accepted methods of assessing the performance and impact of a scientist is calculating the number of citations for their publications. However, such method suffer from certain shortcomings. It has become more and m...
متن کاملHistomorphometric, fractal and lacunarity comparative analysis of sheep (Ovis aries), goat (Capra hircus) and roe deer (Capreolus capreolus) compact bone samples.
Quantitative and qualitative studies dealing with histomorphometry of the bone tissue play a new role in modern legal medicine/forensic medicine and archaeozoology nowadays. This study deals with the differences found in case of humerus and metapodial bones of recent sheep (Ovis aries), goat (Capra hircus) and roedeer (Capreolus capreolus) specimens, both from a qualitative point of view, but m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical and diagnostic research : JCDR
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2013