Accuracy of distal radius positioning using an anatomical plate.

نویسندگان

  • Joy C Vroemen
  • Johannes G G Dobbe
  • Inger N Sierevelt
  • Simon D Strackee
  • Geert J Streekstra
چکیده

Over the past decade, several anatomical plates have been introduced to improve the result of open reduction and internal fixation of the distal radius. Using 3-dimensional imaging techniques, the authors studied the accuracy and reproducibility of distal radius positioning using anatomical plates.Distal radius fractures and the correction of these fractures were simulated with plastic bone models of radii. The authors simulated a defect by removing an arbitrary wedge shape from the artificial radii. Two surgeons corrected these fractures by placing 2 anatomical plate types according to the plate manufacturers' instructions. The residual positioning errors of the distal segment in relation to the unaffected radii were determined using 3-dimensional imaging and were compared with naturally occurring bilateral radius differences in healthy individuals. In many cases, positioning does not agree with differences based on bilateral asymmetry in healthy patients.This study indicated the accuracy of anatomical plates. Positioning an anatomical plate may lead to considerable residual errors in individual patients. Volar distal radius plate shapes differ among plate manufacturers. Therefore, one plate may perform better than another in an individual.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Much are Emergency Medicine Specialists’ Decisions Reliable in the Diagnosis and Treatment of Pediatric Fractures?

  Background: Considering the importance of an early diagnosis and proper decision-making in regards to the treatment of pediatric distal radius and elbow fractures, this study examines emergency medicine specialists’ accuracy in the diagnosis and treatment of these patients. Methods: From 2012 and 2013, children less than 14 years old who were referred to an academic hospital emergency departm...

متن کامل

Treatment of neglected mal:union: of the distal radius: a cases series study

 Background: Mal:::union::: is the most common complication following distal radius fractures. Aim of this study was to evaluate the results of distal radius corrective osteotomy and plate fixation by dorsal approach in the mal:::union:::. Methods: In this retrospective study, 14 patients with neglected distal radius mal:::union::: from 2005 to 2011 were studied. All patients were treated ...

متن کامل

Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy

Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstr...

متن کامل

Various volar shapes of the distal radius and its implications on volar plate osteosynthesis

Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...

متن کامل

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

BACKGROUND Distal radius fracture is the most common fracture of the upper extremity, and approximately 60,000 distal radius fractures occur annually in Korea. Internal fixation with an anatomical volar locking plate is widely used in the treatment of unstable distal radius fractures. However, most of the currently used distal radius anatomical plate systems were designed based on the anatomica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2013