Variability in uptake efficiency for pulsed versus constant concentration delivery of inhaled nitric oxide
نویسندگان
چکیده
BACKGROUND Nitric oxide (NO) is currently administered using devices that maintain constant inspired NO concentrations. Alternatively, devices that deliver a pulse of NO during the early phase of inspiration may have use in optimizing NO dosing efficiency and in extending application of NO to long-term use by ambulatory, spontaneously breathing patients. The extent to which the amount of NO delivered for a given pulse sequence determines alveolar concentrations and uptake, and the extent to which this relationship varies with breathing pattern, physiological, and pathophysiological parameters, warrants investigation. METHODS A mathematical model was used to analyze inhaled nitric oxide (NO) transport through the conducting airways, and to predict uptake from the alveolar region of the lung. Pulsed delivery was compared with delivery of a constant concentration of NO in the inhaled gas. RESULTS Pulsed delivery was predicted to offer significant improvement in uptake efficiency compared with constant concentration delivery. Uptake from the alveolar region depended on pulse timing, tidal volume, respiratory rate, lung and dead space volume, and the diffusing capacity of the lung for NO (DLNO). It was predicted that variation in uptake efficiency with breathing pattern can be limited using a pulse time of less than 100 ms, with a delay of less than 50 ms between the onset of inhalation and pulse delivery. Nonlinear variation in uptake efficiency with DLNO was predicted, with uptake efficiency falling off sharply as DLNO decreased below ~50-60 ml/min/mm Hg. Gas mixing in the conducting airways played an important role in determining uptake, such that consideration of bulk convection alone would lead to errors in assessing efficiency of pulsed delivery systems. CONCLUSIONS Pulsed NO delivery improves uptake efficiency compared with constant concentration delivery. Optimization of pulse timing is critical in limiting intra- and inter-subject variability in dosing.
منابع مشابه
Administration of nitric oxide into open lung regions: delivery and monitoring.
BACKGROUND Pulsed administration of nitric oxide has proven effective in relieving pulmonary hypertension and in improving oxygenation. With this delivery method the nitric oxide administration to low ventilated lung regions is avoided with subsequent enhancement in oxygenation. This study presents (i) pulsed administration technique for nitric oxide during artificial ventilation, (ii) evaluati...
متن کاملClinical perspectives with long-term pulsed inhaled nitric oxide for the treatment of pulmonary arterial hypertension
Pulmonary arterial hypertension (PAH) is a chronic, progressive disease of the pulmonary vasculature with a high morbidity and mortality. Its pathobiology involves at least three interacting pathways - prostacyclin (PGI(2)), endothelin, and nitric oxide (NO). Current treatments target these three pathways utilizing PGI(2) and its analogs, endothelin receptor antagonists, and phosphodiesterase t...
متن کاملAn injection and mixing element for delivery and monitoring of inhaled nitric oxide
BACKGROUND Inhaled nitric oxide (NO) is a selective pulmonary vasodilator used primarily in the critical care setting for patients concurrently supported by invasive or noninvasive positive pressure ventilation. NO delivery devices interface with ventilator breathing circuits to inject NO in proportion with the flow of air/oxygen through the circuit, in order to maintain a constant, target conc...
متن کاملNitric oxide administration using constant-flow ventilation.
Nitric oxide (NO) gas is known as both a vasodilator and a toxin. It can react with oxygen to form compounds more toxic than itself, such as nitrogen dioxide (NO2). The reactions are time dependent; thus, infusing NO into breathing circuits as close to ventilated subjects as possible may help minimize toxic byproduct exposure. Unfortunately, flow rates commonly used with mechanical ventilation ...
متن کاملInhaled fluticasone decreases bronchial but not alveolar nitric oxide output in asthma.
Exhaled nitric oxide (NO) concentration is a noninvasive measure of airway inflammation and is increased in asthma. Inhaled glucocorticoids decrease exhaled NO concentration, but the relative contributions of alveolar and bronchial levels to the decrease in exhaled NO concentration are unknown. Alveolar NO concentration and bronchial NO flux can be separately approximated by measuring exhaled N...
متن کامل