Automatic Approach for Calibrating Off-the-shelf Digital Cameras
نویسندگان
چکیده
Recent developments of digital cameras in terms of size of Charged Coupled Device (CCD) arrays and reduced costs are leading to their applications to traditional as well as new photogrammetric, surveying, and mapping functions. Digital cameras, intended to replace the conventional film based mapping cameras, are becoming available along with many smaller format digital cameras capable of precise measurement applications. All such cameras require careful assessment to determine their metric characteristics, which are essential to carry out photogrammetric activities. These characteristics include estimates of the calibrated focal length, location of the principal point relative to the array coordinate system, lens distortion, and the short and long-term stability of these quantities. These characteristics are known collectively as the Interior Orientation Parameters (IOP). Current calibration methods are based on traditional test fields with numerous distinct targets, which have to be professionally surveyed prior to the calibration procedure in order to precisely determine their three-dimensional coordinates. Establishing, surveying, and maintaining traditional calibration test fields are very expensive and not easy tasks for non-photogrammetric users of digital cameras. This paper relates to the development of a new laboratory calibration procedure that requires an easy-to-establish calibration test field (group of straight lines). In addition, the whole calibration process can be automatically carried out with minimal human interaction. It is expected that this calibration procedure would provide a good tool for studying the short and long-term stability of off-the-shelf digital cameras. In addition, it will give a great push to using those cameras in large scale mapping applications as well as various close range photogrammetric activities.
منابع مشابه
New Approach for Calibrating Off-the-shelf Digital Cameras
Recent developments of digital cameras in terms of size of Charged Coupled Device (CCD) arrays and reduced costs are leading to their applications to traditional as well as new photogrammetric surveying and mapping functions. Digital cameras, intended to replace conventional film based mapping cameras, are becoming available along with many smaller format digital cameras capable of precise meas...
متن کاملStability Analysis and Geometric Calibration of Off-the-Shelf Digital Cameras
Recent developments of digital cameras in terms of the size of a Charged Coupled Device (CCD) and Complementary Metal Oxide Semiconductor (CMOS) arrays, as well as reduced costs, are leading to their applications in traditional and new photogrammetric, surveying, and mapping functions. Such cameras require careful calibration to determine their metric characteristics, as defined by the Interior...
متن کاملComparative Geometric and Radiometric Evaluation of Mobile Phone and Still Video Cameras
This paper examines the potential of mobile phones to be used as front-end sensors for photogrammetric procedures and applications. For this purpose, two mobile phone cameras (Sony Ericsson K750i and Nokia N93) were calibrated over an indoor 3D testfield, using a self-calibrating bundle adjustment. Geometric accuracy tests were carried out in order to evaluate their metric performances and to c...
متن کاملMetric Accurac Testing with Mobile Phone Cameras
This paper examines the potential of mobile phones to be used as a front-end sensor for photogrammetric procedures and applications. For this purpose we are calibrating two mobile phones (Sony Ericsson K750i and Nokia N93) over our indoor 3D testfield, using self-calibration. Using the same testfield we are performing accuracy tests in order to evaluate the metric performance and comparing them...
متن کاملEvaluation of Metric Performance of Mobile Phone Cameras
This paper examines the potential of mobile phones to be used as a front-end sensor for photogrammetric procedures and applications. For this purpose we are calibrating two mobile phones (Sony Ericsson K750i and Nokia N93) over our indoor 3D testfield, using self-calibration. Using the same testfield we are performing accuracy tests in order to evaluate the metric performance and comparing them...
متن کامل