Electronic assessment of peri-implant mucosal esthetics around three implant-abutment configurations: a randomized clinical trial.
نویسندگان
چکیده
OBJECTIVES To objectively assess the influence that three different implant-abutment interface designs had on peri-implant mucosal esthetics at 1 year post-implant placement via the pink esthetic score (PES). Additionally, to demonstrate the novel employment of a tablet-based digital imaging format to reliably assess and score clinical images as part of a multicenter clinical trial according to PES criteria. MATERIALS AND METHODS Adult subjects (n = 141) with healed tooth-bound edentulous sites in the anterior maxilla as well as first premolar region were randomized to receive one of three different implant-abutment interface designs (conical interface = CI; flat-to-flat interface = FI; or platform switch interface = PS). Immediate provisionalization was performed with prefabricated titanium abutments, with definitive custom CAD/CAM zirconia abutments and all-ceramic cement-based crowns being delivered 12-week post-implant placement. Bilateral (anterior sites) or unilateral (premolar sites) digital clinical photographs were made at 1, 3, 6, and 12 months post-implant placement. Five calibrated faculty evaluators of different clinical backgrounds scored images during a 4-week timeframe on a standardized, tablet-based, digital imaging format. RESULTS Six hundred and forty-nine clinical photographs were evaluated resulting in a total of 3245 sum PES values and 22,715 individual PES values. Faculty evaluator intra- and inter-rater reliability was found to be "strong" (ICC = 0.84) and "substantial" (ICC = 0.64), respectively, demonstrating repeatability of both the PES, evaluator calibration, and standardization of tablet-based scoring. All implant-abutment interface groups demonstrated significant improvements in mean sum PESs up to 1 year, with the largest improvement between restoration delivery and 6 months. No significant differences were found between groups in mean sum PESs both for individual study visits as well as for changes between study visits. CONCLUSIONS No significant differences in mean sum PESs were found between subjects randomized to three different implant-abutment interfaces. However, significant differences were found as a function of time for all three groups, with the largest improvement in mean sum PESs occurring between definitive abutment and restoration delivery and 6 months. Use of electronic, tablet-based digital imaging scoring formats represents a novel and repeatable methodology for scoring PES images in large, multicenter clinical trials.
منابع مشابه
Interaction of titanium, zirconia and lithium disilicate with peri-implant soft tissue: study protocol for a randomized controlled trial
BACKGROUND Against the background of increasing use of dental implants, and thus an increasing prevalence of implant-associated complications, a deeper understanding of the biomolecular mechanisms in the peri-implant tissue is needed. Peri-implant soft tissue is in direct contact with transmucosal dental implant abutments. The aim of this trial is to distinguish the biomolecular and histologica...
متن کاملImpact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis
OBJECTIVE To address the focused question, is there an impact of platform switching (PS) on marginal bone level (MBL) changes around endosseous implants compared to implants with platform matching (PM) implant-abutment configurations? MATERIAL AND METHODS A systematic literature search was conducted using electronic databases PubMed, Web of Science, Journals@Ovid Full Text and Embase, manual ...
متن کاملBiologic Width around Dental Implants: An Updated Review
Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...
متن کاملInfluence of Abutment Color and Mucosal Thickness on Soft Tissue Color.
PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety pati...
متن کاملInfluence of Restorative Materials on Color of Implant-Supported Single Crowns in Esthetic Zone: A Spectrophotometric Evaluation
Restorations of 98 implant-supported single crowns in anterior maxillary area were divided into 5 groups: zirconia abutment, titanium abutment, and gold/gold hue abutment with zirconia coping, respectively, and titanium abutment with metal coping as well as gold/gold hue abutment with metal coping. A reflectance spectrophotometer was used to evaluate the color difference between the implant cro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2016