OBJECTIVES To evaluate the quality of images obtained with 3D balanced fast-field echo whole heart (WH3D) MRI sequences for assessing the coronary anastomosis and coronary stenosis in patients with D-transposition of the great arteries who have undergone the Jatene switch procedure. MATERIAL AND METHODS We retrieved 100 WH3D studies done in 83 patients who had undergone the Jatene switch procedure from our pediatric cardiac MRI database; 84 of these studies fulfilled the criteria for inclusion in the study. We evaluated coronary stenoses on WH3D MR images and their correlation with coronary CT or angiography images. We retrospectively studied the quality of the images of the proximal coronary arteries using a four-point scale and correlating the findings with age, heart rate, and heart size. RESULTS Of the 84 studies, 4 (4.8%) were of a quality considered «insufficient for diagnosis», 7 (8.3%) were considered «fair», 23 (27.4%) «good», and 50 (59.5%) «excellent». The quality of the image of the coronary arteries was significantly correlated with heart rate. MRI detected stenosis in the origin of the coronary arteries in 9 (10.7%) studies. CONCLUSION Images obtained with the WH3D MRI sequence in patients who had undergone the Jatene procedure were of diagnostic quality in most cases and were better in patients with lower heart rates. In 10.7%, stenosis in the origin of the coronary arteries that required new studies was detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Cardiovascular Magnetic Resonance Imaging in Postoperative Follow-Up After the Arterial Switch Operation for Transposition of the Great Arteries.

Cardiovascular magnetic resonance (MR) plays a major role in the evaluation of patients with transposition of the great arteries, especially during follow-up after surgical intervention such as the arterial switch operation (ASO). It is recommended in recent guidelines that cardiovascular MR should be integrated in the routine evaluation of all postoperative patients with transposition of the g...

متن کامل

Role of Cardiovascular Magnetic Resonance Imaging in Postoperative Follow-Up After the Arterial Switch Operation for Transposition of the Great Arteries

Cardiovascular magnetic resonance (MR) plays a major role in the evaluation of patients with transposition of the great arteries, especially during follow-up after surgical intervention such as the arterial switch operation (ASO). It is recommended in recent guidelines that cardiovascular MR should be integrated in the routine evaluation of all postoperative patients with transposition of the g...

متن کامل

A 33-day-old Infant with the Transposition of the Great Arteries; A Rare Case Report

Dextro-transposition of the great arteries (d-TGA) is the one most common cyanotic congenital heart disease in neonates. The discordant ventriculoarterial arrangement results in parallel circulation, it so is vital to understand the management. We report a rare interesting but critical case of 33-day-old boy who developed cyanosis and had transposition of great arteries combined with interrupte...

متن کامل

Role of Cardiovascular Magnetic Resonance Imaging in Postoperative Follow-Up After the Arterial Switch Operation for Transposition of the Great Arteries

Cardiovascular magnetic resonance (MR) plays a major role in the evaluation of patients with transposition of the great arteries, especially during follow-up after surgical intervention such as the arterial switch operation (ASO). It is recommended in recent guidelines that cardiovascular MR should be integrated in the routine evaluation of all postoperative patients with transposition of the g...

متن کامل

Role of Cardiovascular Magnetic Resonance Imaging in Postoperative Follow-Up After the Arterial Switch Operation for Transposition of the Great Arteries

Cardiovascular magnetic resonance (MR) plays a major role in the evaluation of patients with transposition of the great arteries, especially during follow-up after surgical intervention such as the arterial switch operation (ASO). It is recommended in recent guidelines that cardiovascular MR should be integrated in the routine evaluation of all postoperative patients with transposition of the g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologia

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2015