Multidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation.
نویسندگان
چکیده
Multidetector row computed tomographic (MDCT) assessment of aortic annulus dimensions and frame position and deployment have been associated with paravalvular aortic regurgitation (PAVR) after transcatheter aortic valve implantation (TAVI). The present evaluation investigated the (pre- and postprocedure) MDCT associates of PAVR ≥2+. In total, 123 patients referred for TAVI underwent clinical evaluation, transthoracic echocardiography, and pre- and post-TAVI MDCT. Pre-TAVI MDCT measurements of the aortic annular dimensions and post-TAVI MDCT evaluation of the position and deployment of the prosthesis in the native annulus were performed. At 1-month follow-up, PAVR ≥2+ was observed in 25 patients (20%). The difference between the MDCT-derived maximum aortic annulus and the nominal diameters of the implanted prosthesis (odds ratio 1.912, p = 0.002) and shallow position of the frame in the left ventricular outflow tract (<2 mm) (odds ratio 4.865, p = 0.017) were independently related to significant PAVR. A maximum annulus diameter ≥2 mm larger than the nominal frame diameter had 72% sensitivity and 61% specificity to predict PAVR. In conclusion, in patients undergoing TAVI, ≥2-mm difference between maximum aortic annulus and nominal prosthesis diameters and depth of the frame into the left ventricular outflow tract of <2 mm are independently associated with PAVR ≥2+.
منابع مشابه
Is time of renal hypoperfusion an important variable in determining response to renal artery revascularization?
3. Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235–45. 4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before tran...
متن کاملTranscatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve.
OBJECTIVES The aim of this study was to demonstrate the first-in-human feasibility and short-term clinical outcomes with a new balloon-expandable transcatheter heart valve (THV). BACKGROUND The SAPIEN 3 (S3) THV incorporates a paravalvular sealing system, an active 3-dimensional coaxial positioning catheter, and is compatible with a 14-F expandable sheath. METHODS The S3 THV was implanted i...
متن کاملQuantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
OBJECTIVES This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). BACKGROUND The impact of AVC in different locations within the aortic valve complex is incompletely understood. METHODS This study analyzed 150 pa...
متن کاملRelationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
BACKGROUND Multidetector computed tomography is useful for determining the appropriate transcatheter heart valve (THV) size in patients with severe aortic stenosis who are suboptimal surgical candidates. The relationship between adherence to the recommended CoreValve sizing algorithm and clinical outcomes is not known. METHODS AND RESULTS We evaluated 1023 patients with severe aortic stenosis...
متن کاملRelationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve.
BACKGROUND Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. METHODS Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Med...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 112 11 شماره
صفحات -
تاریخ انتشار 2013