The axial misalignment between ocular lens and cornea observed by MRI (I)—At fixed accommodative state

نویسندگان

  • Yin Chang
  • Hsiu-Mei Wu
  • Yu-Fong Lin
چکیده

Lens tilt and decentration relative to the corneal axis are two of the factors which cause aberration in human eyes. Although many techniques have been developed to quantitatively measure these factors, however, they are mostly confined in 2D observations. To extend the view from 2D to 3D, MR imaging technique becomes a good candidate due to its capability of 3D-image reconstruction and with fairly good spatial resolution for that purpose. In this study a total of six eyes of six young students at this Institute were examined by using a 1.5T MRI machine incorporating with a commercial 3-in. surface coil at Taipei Veterans General Hospital. From a 45 degrees flipped reflective mirror, the subject could focus to a target at a distance of 60 cm from the eye for MR imaging in monocular vision. Quadric surface models were used to fit cornea and lens surfaces in the post image processes. Tilts of the two lens surfaces and the decentration of lens centre with respect to corneal axis were determined through coordinate transformations. One month later, retest was carried out on five of the six subjects. The results show that the average tilts of anterior and posterior lens surfaces, and lens decentration are 3.7+/-2.5 degrees, 3.3+/-1.4 degrees and 0.11+/-0.07 mm (H), -0.06+/-0.38 mm (V), respectively, for the test; 2.1+/-2.4 degrees, 1.9+/-1.8 degrees and -0.02+/-0.28 mm (H), -0.45+/-0.28 mm (V) for the retest. No statistically significant difference (by Wilcoxon Signed Ranks test) is revealed for the tilts of both lens surfaces (p(phia)=0.375, p(phip)=0.225) and for decentration (p(H)=0.343, p(V)=0.345) between test and retest in this longitudinal observation. The surface shapes of the ocular anterior components do not seem to be unified by only one type but ellipsoid, elliptic paraboloid, hyperboloid and paraboloid are all possible. Changes in shape type in the ocular anterior components were also found when measured in a period of one month.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does transient increase in axial length during accommodation attenuate with age?

BACKGROUND The aim was to profile transient accommodative axial length changes from early adulthood to advanced presbyopia and to determine whether any differences exist between the responses of myopic and emmetropic individuals. METHODS Ocular biometry was measured by the LenStar biometer (Haag-Streit, Switzerland) in response to zero, 3.00 and 4.50 D accommodative stimuli in 35 emmetropes a...

متن کامل

Variation of axial and oblique astigmatism with accommodation across the visual field

In this study we investigated the impact of accommodation on axial and oblique astigmatism along 12 meridians of the central 30° of visual field and explored the compensation of corneal first-surface astigmatism by the remainder of the eye's optical system. Our experimental evidence revealed no systematic effect of accommodation on either axial or oblique astigmatism for two adult populations (...

متن کامل

بررسی حجم و ابعاد کره چشم و عوامل مرتبط با ان با استفاده از MRI؛ کرمانشاه سال 1392

Abstract Background: Considering the importance of getting informed about the ocular volume and dimensions in treatment and surgical projects, and also the lack of information about the ocular volume in Iran. This investigation was performed in 1392 in Kermanshah. Materials and methods: This cross-sectional study carried out on 60 healthy individuals referred to imaging center at Imam Reza hosp...

متن کامل

A longitudinal study of accommodative changes in biometry during incipient presbyopia.

PURPOSE To profile accommodative biometric changes longitudinally and to determine the influence of age-related ocular structural changes on the accommodative response prior to the onset of presbyopia. METHODS Twenty participants (aged 34-41 years) were reviewed at six-monthly intervals over two and a half years. At each visit, ocular biometry was measured with the LenStar biometer (www.Haag-...

متن کامل

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2007