Computational fluid dynamics analysis of tandem carotid artery stenoses: Investigation of neurological complications after carotid artery stenting.
نویسندگان
چکیده
BACKGROUND Combined extra- and intracranial carotid artery stenoses, particularly involving multiple lesions, show complex hemodynamic properties and represent a therapeutic dilemma. We used computational fluid dynamics (CFD) to investigate whether insufficient cerebral blood flow (CBF) in a 70-year-old man with tandem stenoses was the cause of aphasia and right hemiparesis after carotid artery stenting (CAS) of the extracranial stenosis. METHOD Three-dimensional digital subtraction angiography (3D-DSA) was performed before and after balloon angioplasty and CAS in the patient. The geometrical and rheological conditions of the carotid arteries were determined, and computational meshes were generated from the patient-specific 3D-DSA datasets. CFD analysis was performed, and hemodynamic parameters such as mass flow, pressure, fractional flow reserve, and streamlines were calculated. RESULTS Post-CAS simulations showed that the percentage of internal carotid artery mass flow from common carotid artery mass flow increased from 9% to 14% and CBF improved by only 5%. CONCLUSIONS CFD analysis suggested that the neurological complications were caused by insufficient CBF rather than embolic events, and in tandem carotid stenoses, CAS for an extracranial lesion alone may not always sufficiently increase CBF. CFD enabled the noninvasive quantitative estimation of the effects of CAS of each stenotic segment on carotid flow.
منابع مشابه
ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملCarotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion
Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...
متن کاملPredictors of stroke complicating carotid artery stenting.
BACKGROUND The evolving technique of carotid stenting is being evaluated as an alternative to endarterectomy. Identification of the factors that predispose a patient to neurological complications would facilitate further refinement of the technique and optimize patient selection. METHODS AND RESULTS We analyzed the impact of various clinical, morphological, and procedural determinants on the ...
متن کاملPostprocedural emboli in carotid artery stenting: where do they come from?
Stenting: Where Do They Come From? To the Editor: We read with great interest the study by Sztriha et al1 evaluating the early clinical outcome in a large sample of unprotected carotid artery stenting procedures. Although randomized studies comparing endovascular treatment with endarterectomy are showing encouraging results in favor of the endovascular approach,2,3 cerebrovascular complications...
متن کاملCoronary angiography in patients undergoing carotid artery stenting shows a high incidence of significant coronary artery disease.
OBJECTIVE To assess the incidence, morphology, and associated clinical symptoms of coronary artery disease in patients undergoing elective carotid artery stenting. METHODS In a prospective observational study at a tertiary care centre (university teaching hospital) 444 consecutive patients underwent elective stenting of the carotid artery. Twenty four patients had to be ruled out because of u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Technology and health care : official journal of the European Society for Engineering and Medicine
دوره 24 5 شماره
صفحات -
تاریخ انتشار 2016