Correcting anterior corneal aberration and variability of lens movements in keratoconic eyes with back-surface customized soft contact lenses.

نویسندگان

  • Minghan Chen
  • Ramkumar Sabesan
  • Kamran Ahmad
  • Geunyoung Yoon
چکیده

Customized contact lenses are limited in their correction performance, especially on irregular corneas, owing to decentration and rotation of the lenses. To overcome this limitation, we proposed to customize the back surface of soft contact lenses to match the anterior irregular corneal surface. These lenses were designed to correct anterior corneal aberrations and to improve lens stability. Although in keratoconic eyes the anterior corneal aberrations were effectively corrected, significant residual aberrations were observed. The internal optics, especially the posterior surface of the cornea, was the main source of these residual aberrations. Compared with conventional soft contact lenses, lens stability, on average over three eyes, was improved by a factor of 2 for horizontal and vertical decentrations and a factor of 5 in rotational orientation with the back-surface customized lenses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes.

Higher-order aberration correction in abnormal eyes can result in significant vision improvement, especially in eyes with abnormal corneas. Customized optics such as phase plates and customized contact lenses are one of the most practical, nonsurgical ways to correct these ocular higher-order aberrations. We demonstrate the feasibility of correcting higher-order aberrations and improving visual...

متن کامل

Generation of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation

Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...

متن کامل

Corneal aberration changes after rigid gas permeable contact lens wear in keratokonic patients

PURPOSE To determine the short-term effect of rigid gas permeable (RGP) contact lenses on corneal aberrations in keratoconic patients. METHOD Sixteen keratoconic eyes with no history of RGP lens wear were included. They all had corneal aberrometry using Pentacam, and different aberration indices of the anterior and posterior surfaces of the cornea were measured before and 3 months after fitti...

متن کامل

Higher-order aberrations due to the posterior corneal surface in patients with keratoconus.

PURPOSE This study was designed to investigate higher-order aberrations (HOAs) due to the posterior corneal surface in keratoconic eyes compared with normal eyes. METHODS We studied 24 normal and 28 keratoconic eyes. The anterior/posterior corneal heights and pachymetric data were obtained with a rotating Scheimpflug camera. HOAs for 6 mm pupils were calculated from the differences between th...

متن کامل

On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry.

PURPOSE Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes. METHODS We measured total and anterior-surface aberrations in four subjects, who were all long-term RGP contact lens wearers. The anterior-surface wave aberration was obtained from videokeratographic elevation maps, and ocular wave aberration was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 32 21  شماره 

صفحات  -

تاریخ انتشار 2007