Risk factors for aseptic loosening of Müller-type straight stems

نویسندگان

  • Martin Clauss
  • Silke Gersbach
  • Andre Butscher
  • Thomas Ilchmann
چکیده

Background and purpose Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)). Methods We investigated 828 total hip replacements, which were followed prospectively in our in-house register. All stems were operated in the same setup, using Sulfix-6 bone cement and a second-generation cementing technique. Demographic and design-specific risk factors were analyzed using an adjusted Cox regression model. Results The 4 versions showed marked differences in 15-year stem survival with aseptic loosening as the endpoint: 94% (95% CI: 89-99) for MSS Co, 83% (CI: 75-91) for SL Co, 81% (CI: 76-87) for MSS Ti and 63% (CI: 56-71) for SL Ti. Cox regression analysis showed a relative risk (RR) for aseptic loosening of 3 (CI: 2-5) for stems made of Ti and of 2 (CI: 1-2) for the SL design. The RR for aseptic stem loosening increased to 8 (CI: 4-15) when comparing the most and the least successful designs (MSS Co and SL Ti). Interpretation Cemented Müller-type straight stems should be MSS-shaped and made of a material with high flexural strength (e.g. cobalt-chrome). The surface finish should be polished (Ra < 0.4 µm). These technical aspects combined with modern cementing techniques would improve the survival of Müller-type straight stems. This may be true for all types of cemented stems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Similar effect of stem geometry on radiological changes with 2 types of cemented straight stem

BACKGROUND AND PURPOSE There are 2 basic principles in cemented stem fixation: shape-closed and force-closed. We investigated 2 shape-closed straight stems, the Müller (MSS) and the Virtec (VSS), which differ only in geometrical cross section, to determine whether the difference in stem shape would affect the radiological results or long-term survival. PATIENTS AND METHODS We included 711 hip...

متن کامل

Sixteen-year follow-up of the cemented spectron femoral stem for hip arthroplasty.

Clinical and radiographic follow-up was performed on a consecutive series of 105 patients who underwent 120 total hip arthroplasties at the authors' institution from 1983 to 1988 with a straight, cobalt-chrome femoral stem implanted using a second-generation cementing technique. The mean age at the time of surgery was 68.5 years, and the mean follow-up was 16 years. At 16 years' follow-up, the ...

متن کامل

Long-term survival of a cemented titanium-aluminium-vanadium alloy straight-stem femoral component.

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean f...

متن کامل

Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty

BACKGROUND We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant. METH...

متن کامل

The BCL2 -938C>A Promoter Polymorphism Is Associated with Risk for and Time to Aseptic Loosening of Total Hip Arthroplasty.

Aseptic loosening is a major cause of revision surgery of total hip arthroplasty (THA). Only few host factors affecting aseptic loosening have been identified until now, although they are urgently needed to identify and possibly treat those patients at higher risk for aseptic loosening. To determine whether the functional single nucleotide polymorphism (SNP) c.-938C>A (rs2279115), located in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 84  شماره 

صفحات  -

تاریخ انتشار 2013