Synchrotron radiation microbeam X-ray fluorescence analysis of zinc concentration in remineralized enamel in situ.

نویسندگان

  • Tsunenori Matsunaga
  • Hidetaka Ishizaki
  • Shuji Tanabe
  • Yoshihiko Hayashi
چکیده

OBJECTIVE Remineralization is an indispensable phenomenon during the natural healing process of enamel decay. The incorporation of zinc (Zn) into enamel crystal could accelerate this remineralization. The present study was designed to investigate the concentration and distribution of Zn in remineralized enamel after gum chewing. METHODS The experiment was performed at the Photon Factory. Synchrotron radiation was monochromatized and X-rays were focused into a small beam spot. The X-ray fluorescence (XRF) from the sample was detected with a silicon (Si) (lithium (Li)) detector. X-ray beam energy was tuned to detect Zn. The examined samples were small enamel fragments remineralized after chewing calcium phosphate-containing gum in situ. The incorporation of Zn atom into hydroxyapatite (OHAP), the main component of enamel, was measured using Zn K-edge extended X-ray absorption fine structure (EXAFS) with fluorescence mode at the SPring-8. RESULTS A high concentration of Zn was detected in a superficial area 10-microm deep of the sectioned enamel after gum chewing. This concentration increased over that in the intact enamel. The atomic distance between Zn and O in the enamel was calculated using the EXAFS data. The analyzed atomic distances between Zn and O in two sections were 0.237 and 0.240 nm. CONCLUSION The present experiments suggest that Zn is effectively incorporated into remineralized enamel through the physiological processes of mineral deposition in the oral cavity through gum-chewing and that Zn substitution probably occurred at the calcium position in enamel hydroxyapatite.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective assessment of radiation dose by Fluorescence In Situ Hybridization and evaluation of stable chromosomal aberrations

Estimation of absorbed dose for radiation workers or person involved in different radiological accident is the aim of biodosimetry. Cytogenetic methods are the most current and applicable biodosimetry tools. In chronic or protracted exposure, fluorescence in situ hybridization (FISH), stable chromosomal aberration is used for estimation of absorbed dose. For precise estimation of absorbed dose,...

متن کامل

A Microbeam Small-Angle X-ray Scattering Study on Enamel Crystallites in Subsurface Lesion

The early caries lesion in bovine tooth enamel was studied by two different X-ray diffraction systems at the SPring-8 third generation synchrotron radiation facility. Both allowed us simultaneous measurement of the small and large angle regions. The beam size was 6μm at BL40XU and 50μm at BL45XU. The small-angle scattering from voids in the hydroxyapatite crystallites and the wide-angle diffrac...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins

Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...

متن کامل

Generation of an X-ray microbeam for spectromicroscopy at SPring-8 BL39XU.

A pair of elliptical mirrors (KB mirror) was designed and fabricated to realize an energy tunable x-ray microbeam for spectromicroscopy at SPring-8 BL39XU. As is commonly recognized, the obtainable beam size with the aspherical total reflection mirrors is strongly affected with the slope error of the mirror. Considering that the extremely high brilliance of the undulator radiation from the SPri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of oral biology

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2009