Magnetometers combined with inertial sensors are widely used for orientation estimation, and calibrations are necessary to achieve high accuracy. This paper presents a complete tri-axis magnetometer calibration algorithm with a gyro auxiliary. The magnetic distortions and sensor errors, including the misalignment error between the magnetometer and assembled platform, are compensated after calibration. With the gyro auxiliary, the magnetometer linear interpolation outputs are calculated, and the error parameters are evaluated under linear operations of magnetometer interpolation outputs. The simulation and experiment are performed to illustrate the efficiency of the algorithm. After calibration, the heading errors calculated by magnetometers are reduced to 0.5° (1σ). This calibration algorithm can also be applied to tri-axis accelerometers whose error model is similar to tri-axis magnetometers.
منابع مشابه
Real Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation
Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...
متن کاملThe TableSat Platform and Its Verifiable Control Software
The TableSat single degree-of-freedom tabletop satellite platform was developed to support education and research activities in embedded software and control systems. This paper describes the TableSat system, actuated by a pair of computer fans as thrusters, and then focuses on the evolution of its software for sensor calibration and fault-tolerant control. Sensor systems include a three-axis m...
متن کاملComplete Triaxis Magnetometer Calibration in the Magnetic Domain
This paper presents an algorithm for calibrating erroneous tri-axis magnetometers in the magnetic field domain. Unlike existing algorithms, no simplification is made on the nature of errors to ease the estimation. A complete error model, including instrumentation errors (scale factors, nonorthogonality, and offsets) and magnetic deviations (soft and hard iron) on the host platform, is elaborate...
متن کاملAnalysis and calibration of the gyro bias caused by geomagnetic field in a dual-axis rotational inertial navigation system
A rotational inertial navigation system (RINS) has been wildly used in long term marine navigation. In a dual-axis RINS, with all constant biases averaged out, the errors which can not be averaged out become the main error source. In this paper, the gyro geomagnetic biases of a dual-axis RINS are modelled, analysed and calibrated. The gyro geomagnetic biases are proved unable to be averaged out...
متن کاملThe Search Coil Magnetometer for THEMIS
THEMIS instruments incorporate a tri-axial Search Coil Magnetometer (SCM) designed to measure the magnetic components of waves associated with substorm breakup and expansion. The three search coil antennas cover the same frequency bandwidth, from 0.1 Hz to 4 kHz, in the ULF/ELF frequency range. They extend, with appropriate Noise Equivalent Magnetic Induction (NEMI) and sufficient overlap, the ...