BACKGROUND This study was performed to determine independent predictors of long-term outcome after percutaneous balloon dilation of congenital pulmonary valve stenosis. Smaller follow-up series of patients after balloon pulmonary valvuloplasty have shown inconsistent results regarding the independent relation between prognostic factors and long-term outcome, as many patient selection and technical factors are correlated. METHODS AND RESULTS Follow-up data were obtained for 533 patients from 22 institutions at up to 8.7 years after an initial balloon pulmonary valvuloplasty. Patients were grouped based on defined long-term outcomes, and the independent effects of patient selection and technical factors were sought in multivariate statistical analyses. At follow-up, 23% of patients were noted to have an outcome judged to be suboptimal because of either a residual right ventricle to pulmonary artery peak systolic gradient of > or = 36 mm Hg or further treatment of pulmonary stenosis requiring repeat balloon pulmonary valvuloplasty or surgical therapy. Significant independent predictors of a suboptimal long-term outcome included an earlier study year of the initial valvuloplasty (adjusted odds ratio, 0.71 per consecutive year), a small valve hinge point diameter (0.81 per 1-mm increase), and a higher immediate residual gradient (1.32 per 10 mm Hg increase). A smaller ratio of balloon to valve hinge point diameter significantly predicted suboptimal outcomes for patients with valve morphologies classified as typical (0.52 per 0.1 increase in ratio) and complex (primarily postsurgical valvotomy, 0.43) but not for patients with dysplastic (0.95) or combined morphologies (dysplasia with commissural fusion, 1.01). Patient age, the presence of Noonan's syndrome or associated cardiac lesions, pre-balloon valvuloplasty hemodynamic parameters, and the use of a simultaneous double-balloon technique did not independently predict follow-up outcomes. CONCLUSIONS Accurate prognostication after balloon pulmonary valvuloplasty depends on the careful determination of valvar anatomy. The use of an appropriate ratio of balloon to valve hinge point diameter in the setting of typical valve morphology will optimize the chance of long-term success.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نارسایی دریچه پولمونر پس از ترمیم با بالون در کودکان مبتلا به تنگی این دریچه

Background: Pulmonary valve stenosis (PS) is one of the most common congenital heart disease in children. Isolated pulmonary stenosis is the most common form of pulmonary stenosis. Isolated Pulmonary stenosis is responsible for 8 to 10 percent of congenital heart disease. Balloon valvuloplasty is the choice of treatment for this cardiac disease. One of the most important complications of this d...

متن کامل

Balloon aortic valvuloplasty: results of the Valvuloplasty and Angioplasty of Congenital Anomalies Registry.

Data from 204 children and infants who underwent aortic balloon valvuloplasty between 1982 and 1986, reported to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry, were reviewed. Valvuloplasty was successful in 192 of 204 children, reducing the peak systolic left ventricular ejection gradient from 77 +/- 2 to 30 +/- 1 mm Hg, p less than 0.001. The same degree of aortic stenosis...

متن کامل

Independent Predictors of Long-term Results After Balloon Pulmonary Valvuloplast

Background This study was performed to determine independent predictors of long-term outcome after percutaneous balloon dilation of congenital pulmonary valve stenosis. Smaller follow-up series of patients after balloon pulmonary valvuloplasty have shown inconsistent results regarding the independent relation between prognostic factors and longterm outcome, as many patient selection and technic...

متن کامل

Balloon Pulmonary Valvuloplasty in Adults with Congenital Valvular Pulmonary Stenosis

Background: Balloon valvuloplasty has been used for congenital valvular pulmonary stenosis (PS) in pediatric patients as a conventional treatment. The purpose of this study was to further investigate the safety, immediate and long-term results of balloon valvuloplasty in adults with congenital valvular pulmonary stenosis. Method and Result: We analyzed hemodynamic data of 12 patients who underw...

متن کامل

Immediate, short, intermediate and long-term results of balloon valvuloplasty in congenital pulmonary valve stenosis.

Transluminal balloon valvuloplasty is an alternative to surgical valvotomy for congenital pulmonary valve stenosis. The aim of this study was to evaluate the long term results (to 13.5 years) of balloon pulmonary valvuloplasty. From June 1998 to January 2012, percutaneous balloon pulmonary valvuloplasty for congenital pulmonary valve stenosis was performed in 98 patients (50 males, 48 females, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 4  شماره 

صفحات  -

تاریخ انتشار 1994