Reproducibility of the signal-averaged electrocardiogram using individual lead analysis.

نویسندگان

  • J Aganauskiene
  • L Sörnmo
  • R Atarius
  • C Blomström-Lundqvist
چکیده

The aim of the study was to evaluate the immediate reproducibility of time domain parameters in the signal averaged electrocardiogram using a new method for endpoint determination in individual Frank leads. The method is based on a statistical model of the electrocardiogram (ECG) in which maximum likelihood (ML) estimation is employed. The reproducibility of the ML method was compared to that of conventional time domain analysis using the vector magnitude (VM) of Frank leads. Fifty-nine patients were included in the study and two consecutive ECGs were recorded for signal averaging. The results showed that the mean of the absolute difference of the filtered QRS duration (QRSD) between two consecutive recordings was significantly lower for the ML method than the conventional method when employing 60 Hz highpass filtering (2.1 +/- 2.2 ms vs 5.9 +/- 10.2 ms, P < 0.05). Moreover, the ML method resulted in a significantly longer QRSD compared to the VM-based method (P < 0.05). The terminal amplitude of the QRS complex (RMS40) showed a greater variability than the QRSD for both methods, although the ML method was associated with a higher reproducibility than the VM method for the 60 Hz filter. These findings may contribute to a better identification of patients at high risk of ventricular arrhythmias. A reduction in the number of measurement errors has important implications when QRS changes are analysed over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

A New Approach to Detect Congestive Heart Failure Using Symbolic Dynamics Analysis of Electrocardiogram Signal

The aim of this study is to show that the measures derived from Electrocardiogram (ECG) signals many a time perform better than the same measures obtained from heart rate (HR) signals. A comparison was made to investigate how far the nonlinear symbolic dynamics approach helps to characterize the nonlinear properties of ECG signals and HR signals, and thereby discriminate between normal and cong...

متن کامل

A New Approach to Detect Congestive Heart Failure Using Symbolic Dynamics Analysis of Electrocardiogram Signal

The aim of this study is to show that the measures derived from Electrocardiogram (ECG) signals many a time perform better than the same measures obtained from heart rate (HR) signals. A comparison was made to investigate how far the nonlinear symbolic dynamics approach helps to characterize the nonlinear properties of ECG signals and HR signals, and thereby discriminate between normal and cong...

متن کامل

Signal-Averaged Electrocardiogram Improved Identification of Late Potentials

Background. This study performed a critical analysis of signal-averaging methods. The objective was to optimize detection of late potentials. Methods and Results. We studied two patient populations: a low-arrhythmia-risk group with no evidence of heart disease and a group with clinically documented ventricular tachycardia (VT). Filtered QRS duration (QRSD) and terminal QRS amplitude (RMS40) wer...

متن کامل

Critical analysis of the signal-averaged electrocardiogram. Improved identification of late potentials.

BACKGROUND This study performed a critical analysis of signal-averaging methods. The objective was to optimize detection of late potentials. METHODS AND RESULTS We studied two patient populations: a low-arrhythmia-risk group with no evidence of heart disease and a group with clinically documented ventricular tachycardia (VT). Filtered QRS duration (QRSD) and terminal QRS amplitude (RMS40) wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 1995