Vent configurations on subjective and objective occlusion effect.

نویسندگان

  • Francis Kuk
  • Denise Keenan
  • Chi-chuen Lau
چکیده

The current study reexamined the effect of vent diameters on objective and subjective occlusion effect (OE) while minimizing two possible sources of variability. Nine hearing-impaired participants with primarily a high-frequency hearing loss were evaluated. Laser shell-making technology was used to make ear inserts of completely-in-the-canal (CIC) hearing aids for the study. This was to minimize any potential slit leakage from the inserts. The vent dimensions were systematically altered during the study. Participants sustained /i/ for 5 sec, and the real-ear occluded response was measured with a custom-made program that performed frequency averaging to reduce response variability. Participants also repeated the phrase "Baby Jeannie is teeny tiny" and rated their own voice. The results showed a systematic change in the objective OE and subjective ratings of OE as the vent diameter was modified. Furthermore, a significant correlation was seen between subjective rating and objective occlusion effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-world performance of a reverse-horn vent.

The present study compared differences in subjective and objective performance in completely-in-the-canal (CIC) hearing aids with conventional uniform 1.5 mm parallel vents and another with a reverse horn vent where the diameter increased from 1.5 mm on the lateral faceplate to 3 mm on the medial opening of the hearing aid. Nine hearing-impaired persons with a high-frequency hearing loss partic...

متن کامل

The occlusion effect in unilateral versus bilateral hearing aids.

The benefit of bilateral hearing aids is well documented, but many hearing-aid users still wear only one aid. It is plausible that the occlusion effect is part of the reason for some hearing-aid users not wearing both hearing aids. In this study we quantified the subjective occlusion effect by asking ten experienced users of bilateral hearing aids and a reference group of ten normal-hearing ind...

متن کامل

Occlusion effect of earmolds with different venting systems.

In this study the occlusion effect was quantified for five types of earmolds with different venting. Nine normal-hearing listeners and ten experienced hearing aid users were provided with conventional earmolds with 1.6 and 2.4 mm circular venting, shell type earmolds with a novel vent design with equivalent cross-sectional vent areas, and nonoccluding soft silicone eartips of a commercial heari...

متن کامل

Observations on the relations among occlusion effect, compliance, and vent size.

In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, compliance explained 59 percent of the variation in vent size, whereas the average low-...

متن کامل

Comparison of vent effects between a solid earmold and a hollow earmold.

BACKGROUND Hollow earmolds have become a popular type of earmold used in thin-tube, microsize hearing aid fittings. It is desirable for clinicians to be familiar with their characteristics and limitations. PURPOSE This investigation compared the effects of vent diameter between a traditional solid earmold and a hollow earmold that is used in modern thin-tube hearing aid fittings. RESEARCH D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 2005