In vitro biomechanical comparison of cervical disk arthroplasty, ventral slot procedure, and smooth pins with polymethylmethacrylate fixation at treated and adjacent canine cervical motion units.

نویسندگان

  • P Filippo Adamo
  • Hirohito Kobayashi
  • Mark Markel
  • Ray Vanderby
چکیده

OBJECTIVE To compare the biomechanical properties of cervical arthroplasty to a ventral slot procedure and pin-polymethylmethacrylate (pin-PMMA) fixation. SAMPLE POPULATION Fresh cadaveric cervical (C2-T1) spines from 6 large dogs. METHODS Four spinal conditions were studied in each spinal specimen: intact, disk arthroplasty, ventral slot, and fixation with smooth pin-PMMA at C5-C6 intervertebral space. Axial compression, torsion, flexion-extension, and lateral bending moments were sequentially tested on each specimen for the 4 spinal conditions. Data from the C3-C4, C4-C5, C5-C6, and C6-C7 vertebral motion units (VMUs) were compared among treatments. RESULTS In axial compression and torsion, the ventral slot procedure allowed significantly less motion than intact, pin-PMMA, and arthroplasty groups at C5-C6. In lateral bending and flexion-extension, pin-PMMA had the least motion of C5-C6, followed by the arthroplasty group, intact spine, and ventral slot, all of which were significantly different from each other. Overall, the artificial disk was better able to mimic the behavior of the intact specimens compared with the ventral slot and pin-PMMA, producing similar displacements in axial compression and rotation in torsion, but more limited motion than intact in flexion-extension and in lateral bending. CONCLUSION Cervical spine specimens with an implanted prosthesis have biomechanical behaviors more similar to an intact spine compared with spinal specimens with ventral slot and pin-PMMA procedures. Cervical arthroplasty may then preserve some of the motion in the affected area after neural decompression while providing distraction. CLINICAL RELEVANCE Cervical arthroplasty should be further investigated in vivo to determine if it is a viable alternative to the ventral slot or pin-PMMA procedures for surgical treatment of cervical diseases in dogs and in particular for treatment of disk-associated caudal cervical spondylomyelopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison between bicortical pin and monocortical screw/polymethylmethacrylate constructs in the cadaveric canine cervical vertebral column.

OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletal...

متن کامل

Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines.

OBJECTIVE To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN In vitro biomechanical evaluation. ANIMALS Cadaveric canine C4-C7 cervical spines (n = 9). METHODS Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while...

متن کامل

Comparison of long terms follow up results in patients with cervical disk disease treated with anterior PEEK cage implantation and without it in Rasoul Akram Hospital

 Background: Anterior interbody fusion of the cervical spine have become the gold standard for treating spinal diseases, hence the aim of this study was to compare long term follow up results in patients with cervical disk disease treated with anterior PEEK cage implantation and without it in anterior approach. Methods: Retrospectively 63 patients with known cervical discogenic disorders who we...

متن کامل

The Bryan Artificial Disc

p0020The cervical spine is a linkage of specialized joints and, like other joints, may be the source of significant pain and functional incapacity with age, trauma, and subsequent degeneration. However unlike other major joints, the traditional perception is that motion in the cervical spine is not a necessity and has been routinely sacrificed for pain relief and functional recovery. For more t...

متن کامل

RUNNING HEAD: Effect of a Cervical Intervertebral Spacer on Construct Stiffness Effect of an Intervertebral Disk Spacer on Stiffness after Monocortical Screw/Polymethylmethacrylate Fixation in Simulated and Cadaveric Canine Cervical Vertebral Columns

Objective: To determine the biomechanical effect of an intervertebral spacer on construct stiffness in a PVC model and cadaveric canine cervical vertebral columns stabilized with monocortical screws/polymethylmethacrylate (PMMA). Study Design: Biomechanical study. Sample population: PVC pipe; cadaveric canine vertebral columns Methods: PVC model – PVC pipe was used to create a gap model mimicki...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary surgery : VS

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2007