Importance of absence of CSF pulsation artifacts in the MR detection of significant myelographic block at 1.5 T.
نویسندگان
چکیده
MR imaging was performed on 21 patients who had high-grade myelographic block due to various diseases in all spinal compartments (extradural, intradural/extramedullary, and intramedullary) and in all portions of the spinal canal (cervical, thoracic, and lumbosacral). Loss of CSF pulsation artifacts due to significant compression of the spinal cord was demonstrated on non-motion-compensated T2-weighted examinations in each case. We believe that the absence of such artifacts on these sequences indicates significant spinal cord compression in patients without classic signs and symptoms of cord compression but with intraspinal disease identified on T1-weighted studies.
منابع مشابه
The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.
PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...
متن کاملImaging Signs in Spontaneous Intracranial Hypotension: Prevalence and Relationship to CSF Pressure.
BACKGROUND AND PURPOSE Patients with spontaneous intracranial hypotension often exhibit low CSF pressure and changes on brain MR imaging and/or evidence of CSF leak on myelography. We investigated whether individual imaging signs of spontaneous intracranial hypotension correlate with measured CSF pressure and how frequently these 2 markers of spontaneous intracranial hypotension were concordant...
متن کاملCerebrospinal Pulsation Hydrodynamics in a 2D Simulation of Brain Ventricles
In this article, dynamics of the cerebrospinal fluid (CSF) was studied, using computational fluid dynamics. Using MRI images of two special cases, a 2-dimensional model of the ventricular system was made. CSF velocity and pressure distribution in ventricular system have high importance since the flow pattern of this liquid has an important effect on intracranial pressure, i.e., ICP, which has a...
متن کاملThe "Hyperdense Paraspinal Vein" Sign: A Marker of CSF-Venous Fistula.
CSF-venous fistula is a recently reported cause of spontaneous intracranial hypotension that may occur in the absence of myelographic evidence of CSF leak. Information about this entity is currently very limited, but it is of potential importance given the large percentage of cases of spontaneous intracranial hypotension associated with negative myelography findings. We report 3 additional case...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 10 5 شماره
صفحات -
تاریخ انتشار 1989