Evaluation of the Olympus AU-510 analyser

نویسندگان

  • Carmen Farré
  • Jesús Velasco
  • Francisco Ramón
چکیده

The selective multitest Olympus AU-510 analyser was evaluated according to the recommendations of the Comision de Instrumentacion de la Sociedad Española de Quimica Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was carried out in two stages: an examination of the analytical units and then an evaluation in routine work conditions. The operational characteristics of the system were also studied.THE FIRST STAGE INCLUDED A PHOTOMETRIC STUDY: dependent on the absorbance, the inaccuracy varies between +0.5% to -0.6% at 405 nm and from -5.6% to 10.6% at 340 nm; the imprecision ranges between -0.22% and 0.56% at 405 nm and between 0.09% and 2.74% at 340 nm. Linearity was acceptable, apart from a very low absorbance for NADH at 340 nm; and the imprecision of the serum sample pipetter was satisfactory.TWELVE SERUM ANALYTES WERE STUDIED UNDER ROUTINE CONDITIONS: glucose, urea urate, cholesterol, triglycerides, total bilirubin, creatinine, phosphate, iron, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyl transferase.The within-run imprecision (CV%) ranged from 0.67% for phosphate to 2.89% for iron and the between-run imprecision from 0.97% for total bilirubin to 7.06% for iron. There was no carryover in a study of the serum sample pipetter. Carry-over studies with the reagent and sample pipetters shows some cross contamination in the iron assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical performance of the selective, automatic multianalyser Olympus AU 5031

The analytical performance of the selective, automatic multianalyser Olympus AU 5031 was evaluated over four months and assessed for practicability for another eight months. The evaluation followed the ECCLS guidelines. Twenty routine parameters were measured. In addition, sodium and potassium were determined on an attached flame photometric unit. Both the agreement between the eights photomete...

متن کامل

Analytical performance of the selective multianalyser Olympus AU 5200

The analytical performance of a selective, automatic multianalyser- the Olympus A U5200 - was tested and assessed for practicability, following ECCLSguidelines. Twenty-two analytes were tested and compared with the Olympus A U5000 analyser. A Hitachi 747 analyser was also included in this survey in order to obtain correlation data for ISE measurements.The imprecision data, expressed as median C...

متن کامل

Letter to the Editor: The effects of hyperlipidaemia, hyperbilirubinaemia and haemolysis on tests performed by the Olympus AU 5000 multiple analyser

Increasing amounts ofIntralipid (Kabivitrum), bilirubin (NBS standard 916) or haemolysate were added to a serum pool of 40 patients, as previously described [1]. Added Intralipid yielded samples with triglyceride levels of 0"8-6-3 g/l, added bilirubin yielded samples having total bilirubin levels of 4-325 mg/1 and added haemolysate yielded samples with haemoglobin concentrations of 0-1"58 g/1. ...

متن کامل

Synthesis of Au Nanoparticles by Thermal, Sonochemical and Electrochemical Methods: Optimization and Characterization

The present study concentrates on the synthesis of Au nanoparticles (AuNPs) using aqueous solution of Polyvinylpyrrolidone (PVP) and tetrachloroaurate by different methods as thermal, sonochemical and electrochemical reduction. The PVP has been used as a reducing agent and acts as a stabilizer for Au nano particles that obtained as principal product. In all synthesis procedures, the active radi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1991