A comparison of 25 gauge Quincke spinal needle with 26 gauge Eldor spinal needle for the elective Caesarian sections: insertion characteristics and complications.
نویسندگان
چکیده
OBJECTIVE The study was designed to compare the insertion characteristics and incidence of PDPH between 25 gauge Quincke needle and 26 gauge Eldor needle for spinal anaesthesia in elective c/s. METHOD 60 pregnant women (aged 19-35 yrs and weighing 58 -67 kg) undergoing elective caesarean section were randomized into group A (Quincke spinal needle group) or group B (Eldor spinal needle group). Spinal anaesthesia was performed with 2.9 ml 0.5% heavy bupivacaine using 25 gauge Quincke spinal needle in group A and 26 Gauge Eldor spinal needle in group B. Onset, time of first identification of backflow of CSF, number of attempts, level of sensory and motor blockade, failure of anaesthesia, inadequate anaesthesia and incidence of PDPH were recorded. RESULT Quincke spinal needle was found easy at insertion, first attempt was successful in 90% of cases, whereas Eldor spinal needle was successful at first attempt in only 60% of cases. Early identification of CSF was seen in Eldor spinal needle group in 3.5 seconds vs. 5.2 seconds in Quincke spinal needle group. Blood mixed CSF was seen in 8 Quincke spinal needle group vs. none in Eldor spinal needle group. Onset was similar between both groups i.e. in 6 minutes. Failure of anaesthesia was none in Eldor spinal needle group vs. 2 in quincke spinal needle group. Height of sensory block achieved was T4 level in 26 parturients,T6 in 1 ,T8 in 1 and no anaesthesia at all in another 2 parturient as compared to T4 level in 29 and T3 in 1 parturient in Eldor spinal needle group. The degree of motor block with the use of Bromage criteria showed a motor score of 1 or 2 in 26 parturients in Quincke spinal needle group vs. same in all cases in Eldor spinal needle group. The total incidence of PDPH was 8.3 % (5 out of 60 parturient) which occurred all in Quincke spinal needle group. 2 parturient who developed severe PDPH required epidural blood patch. CONCLUSION 26 gauge Eldor spinal needle was found to be better than 25 gauge Quincke spinal needle for caesarian sections to decrease the incidence of PDPH, though not all insertion characteristics were in favour of the Eldor needle.
منابع مشابه
The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients
BACKGROUND The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. AIMS The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in ele...
متن کاملDoes Atraucan cause more postdural puncture backache?
BACKGROUND/AIM Postdural puncture backache (PDPB) is the most frequent complaint after spinal anesthesia. In the literature its importance is generally overshadowed by postdural puncture headache. We studied two different kinds of spinal anesthesia needles to compare their technical handling capacities and incidences of PDPB. MATERIALS AND METHODS Data of 256 pregnant female patients undergoi...
متن کاملTransient neurological symptoms after isobaric subarachnoid anesthesia with 2% lidocaine: the impact of needle type.
BACKGROUND The reported incidence of transient neurological symptoms (TNS) after subarachnoid lidocaine administration is as high as 40%. We designed this clinical trial to determine the incidence of TNS with two different pencil-point spinal needles: one-orifice (Atraucan) and two-orifice (Eldor) spinal needles. METHODS Ninety-nine ASA physical status I or II patients undergoing surgical pro...
متن کاملComparison of Spinal Needle Deflection in a Ballistic Gel Model
BACKGROUND Percutaneous diagnostic and therapeutic procedures are commonly used in the treatment of spinal pain. The success of these procedures depends on the accuracy of needle placement, which is influenced by needle size and shape. OBJECTIVES The purpose of this study is to examine and quantify the deviation of commonly used spinal needles based on needle tip design and gauge, using a bal...
متن کاملA comparison study between newly-designed pencil-point and cutting needles in spinal anesthesia.
OBJECTIVES The goal of this single blinded randomized study was to compare the use of routine cutting-tip spinal needle and newly-designed pencil-point Pajunk(AE) in terms of success rate, complications and satisfactions in priests undergoing spinal anesthesia for orthopedic, general and urological surgery at Priest Hospital, Thailand. MATERIAL AND METHOD After Institutional Review Board appr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kathmandu University medical journal
دوره 1 4 شماره
صفحات -
تاریخ انتشار 2003