Changes in corneal biomechanics and applanation tonometry with induced corneal swelling.

نویسندگان

  • William Lau
  • David Pye
چکیده

PURPOSE To investigate the changes in Goldmann applanation tonometry (GAT) and Ocular Response Analyzer (ORA) measurements with corneal edema induced by contact lenses. METHODS Twenty-five healthy, normal subjects (age, 23 ± 2 years) had central corneal radius (CCR), ORA, GAT, and central corneal thickness (CCT) measurements performed in both eyes before a thick, soft hydrogel contact lens was worn with eye closure for 2 hours in one eye. Measurements were repeated immediately after lens removal and every 20 minutes thereafter for the following hour. RESULTS The experimental and control eyes behaved asymmetrically over time (repeated measures analysis of variance [RMANOVA]; P < 0.05) for all variables except CCR. GAT, ORA Goldmann-correlated intraocular pressure (ORAg), and ORA corneal-compensated intraocular pressure (ORAcc) showed comparable overestimations, whereas corneal hysteresis (CH) and corneal resistance factor (CRF) responded to corneal swelling in dissimilar ways (RMANOVA; α = 0.05). The variation in GAT in experimental eyes could be predicted by changes in CRF (0.85 [0.23] mm Hg ΔGAT/mm Hg ΔCRF; P < 0.001), but not by CCT or CH. The covariation of both CH and CRF with CCT was influenced by the presence of corneal swelling (Eye×ΔCCT interaction, P < 0.001 and P = 0.003, respectively). CONCLUSIONS The GAT overestimation caused by small amounts of corneal swelling represents an overall increase in corneal rigidity, which is partially characterized by CRF. In contrast, CH does not appear to usefully quantify biomechanical changes induced by corneal swelling. The accuracy of ORAcc is affected by corneal swelling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Age-Related Changes in Corneal Deformation Dynamics Utilizing Scheimpflug Imaging

PURPOSE To study age-related changes in corneal deformation response to air-puff applanation tonometry. METHODS Fifty healthy subjects were recruited for a prospective study and divided into two equal age groups (≤ 28 and ≥ 50 years old). Up to three measurements by a corneal deformation analyser based on the Scheimpflug principle were performed on the left eye of each subject. Raw Scheimpflu...

متن کامل

Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea

Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The ...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction

PURPOSE The purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA). METHODS This is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients rang...

متن کامل

Applanation pressure function in Goldmann tonometry and its correction.

So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer. All the tables of instrument reading corrections for cornea thickness or cornea curvature radius are based exclusively on measurements. This paper represents an attempt at cr...

متن کامل

Electronic applanation tonometry in corneal edema and keratoplasty.

The effect of corneal edema and the effect of penetrating keratoplasty upon the accuracy of electronic applanation tonometry were studied in rabbits. Pressure readings made directly from cannulas in the anterior chamber correlated well with those made by electronic applanation tonometry both in severe corneal edema and 24 hours after penetrating keratoplasty. The advantages of electronic applan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2011