Possible usefulness of echocardiographic Z-scores in autopsy routine of the foetal great vessels.

نویسندگان

  • A Grzyb
  • J Skrzypecki
  • A Koleśnik
  • C S Niszczota
چکیده

BACKGROUND Abnormal diameters of foetal vessels are common findings in congenital heart defects. However, it is difficult for pathologist to assess whether the diameters of the vessels are normal or not and to compare with echocardiographic data. The Z-score is a dimensionless quantity representing the distance between the raw score and population mean in standard deviation units. Using Z-score, we can compare single cases to average standards in the population. AIM To compare diameters of great arteries measured in specimens fixed in 10% formalin solution to normal values obtained on echocardiography using Z-scores. MATERIAL AND METHODS The study was performed on 43 formalin-fixed normal foetal hearts aged from 19 to 40 weeks of gestation. Each specimen was dissected and the following diameters were measured: aortic valve (AoV), ascending aorta (AAo), descending aorta (DAo), aortic isthmus (AoI), ductus arteriosus (DA), pulmonary trunk valve (PV), and pulmonary arteries (RPA and LPA). Z-score parameters were calculated for all structures using the Foetal Echo Z-score Calculator. RESULTS Z-score values of all measured foetuses were mostly found to fit within the echocardiographic norms, although the most reliable results were obtained for foetuses aged 23 weeks. This group was represented by the highest number of specimens. The minimal and maximal Z-score values were, respectively: AoV -3.45, 1.4; AAo -4.24, -0.11; DAo -2.12, 1.29; PV -3.21, 0.69; RPA -3.4, 0.84; LPA -2.25, 0.31; AoI -1.97, 0.96; DA -3.56, -1.52. CONCLUSIONS The diameters of great arteries measured on autopsy are comparable to the results obtained from echocardiographic measurement. Z-score values for foetal echocardiography can be applied to post-mortem examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تاثیر شمارش حرکات جنین توسط مادر بر میزان دلبستگی مادر- جنین در مادران با اولین بارداری

Background and purpose: Maternal-foetal attachment (MFÂ) is a term which describes the relationship between a pregnant women and her foetus. Mothers with high MFÂ show more confidence in their new role and a better postpartum adjustment. The present study was conducted to determine the effect of counting foetal movement on maternal-foetal attachment. Materials and methods: This interventio...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Foetal growth velocities in twin pregnancies.

A retrospective longitudinal study was performed to quantify foetal growth velocities in twin pregnancies and to determine the effect of variables specific to twin pregnancies on growth velocity. Foetal growth velocity standard deviation (Z) scores were calculated from serial ultrasound data using published singleton reference data for 131 consecutive sets of twins from 30 to 37 weeks' gestatio...

متن کامل

Periodontal Pockets as a Potential Source of Infection: a Case of Possible Odontogenic Septic Pulmonary Embolism

Although dental foci can be sources of bacteremia and bacterial endocarditis, hematogenous spread of infection presented with septic pulmonary embolism apparently is rare. The occurrence of septic pulmonary embolism in patients with periodontal disease without suppurative thrombophlebitis of the great vessels of the neck is well documented but to our knowledge, there is no report on septic pulm...

متن کامل

[Left ventricular outflow tract obstruction in transposition of the great arteries. Correlation between anatomic and echocardiographic findings].

INTRODUCTION AND OBJECTIVES Left ventricle outflow tract obstructions in transposition of the great arteries are frequent. We report the correlations between two-dimensional echocardiographic and autopsy findings to draw attention to the usefulness of this diagnostic method in the preoperative evaluation of these anomalies. MATERIAL AND METHODS Of 73 hearts with transposition of great arterie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Folia morphologica

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2012