Bias and precision of pulse oximeters and arterial oximeters.

نویسندگان

  • B G Nickerson
  • C Sarkisian
  • K Tremper
چکیده

We evaluated measurements of oxygen saturation from four noninvasive pulse oximeters, and two conventional arterial oximeters. Simultaneous measurements were obtained on each instrument on three different occasions in five healthy subjects breathing gas with an FIO2 of 1.00, 0.50, 0.21, 0.17, 0.15, 0.13 and 0.11. Mean bias relative to the sum of oxy-, carboxy-, and methemoglobins ranged from -0.4 to -2.6 percent for the pulse oximeters and +1.8 to -4.2 percent for the conventional oximeters. Two pulse oximeters performed well at all saturations down to 65 percent, while the others showed either increasing or decreasing bias below 80 percent saturation. Precision was approximately 2 percent for all instruments except one conventional oximeter with a precision of 0.7 percent. In the clinically relevant range, the performance of the noninvasive pulse oximeters was similar to conventional oximeters using arterial samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Pulse Oximeters in Detecting Hypoxemia in Patients with Chronic Thromboembolic Pulmonary Hypertension

PURPOSE Pulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2). When oxygen saturation by pulse oximeter (SpO2) overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who spent their daily lives in a poor oxyg...

متن کامل

Variability in estimating shunt from single pulse oximetry measurements.

Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precision of pulse oximeters and the non-linear relationship between virtual shunt and...

متن کامل

Pulse oximetry: theory and applications for noninvasive monitoring.

Noninvasive measurement of arterial oxygen saturation (SaO2) by pulse oximetry is widely acknowledged to be one of the most important technological advances in monitoring clinical patients. Pulse oximeters compute SaO2 by measuring differences in the visible and near infrared absorbances of fully oxygenated and deoxygenated arterial blood. Unlike clinical blood gas analyzers, which require a sa...

متن کامل

Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis.

The objective of this prospective, observational study with consecutive sampling was to assess the reliability, bias, and precision of Nellcor N-395 (N) and Masimo SET Radical (M) pulse oximeters in children with cyanotic congenital heart disease and children with congenital heart disease recovering from cardiopulmonary bypass-assisted surgery admitted to a cardiovascular operating suite and pe...

متن کامل

Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults.

OBJECTIVE The purposes of the study were to: (1) describe the aggregate strength of the relationship of arterial oxygen saturation as measured by pulse oximetry with the standard of arterial blood gas analysis as measured by co-oximetry, (2) examine how various factors affect this relationship, and (3) describe an aggregate estimate of the bias and precision between oxygen saturation as measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 1988