Comparison of direct inoculation and Copan transport systems for isolation of Neisseria gonorrhoeae from endocervical specimens.
نویسندگان
چکیده
Two commercial swab transport systems, Copan Amies gel agar with and without charcoal (Copan Diagnostics, Corona, Calif.), were compared to direct inoculation onto modified Thayer-Martin medium for detection of Neisseria gonorrhoeae in 1,490 endocervical specimens obtained from women attending a sexually transmitted disease clinic. Copan swabs were held in the transport system for 24 h at room temperature prior to inoculation onto modified Thayer-Martin medium. All cultures were incubated at 35 degrees C in 5% CO(2), and bacteria were identified on the basis of Gram stain, oxidase, and biochemical reactions. Copan Amies gel agar transport system without charcoal detected 77 of 81 (95%) direct inoculation culture-positive specimens, and Copan Amies gel agar transport system with charcoal detected 53 of 56 (95%) directly inoculated culture-positive specimens. Copan Amies gel agar without charcoal inoculated after 6 h supported growth of 56 (98%) positive cultures out of only 55 directly inoculated culture-positive specimens. This study demonstrates that Copan swabs represent a reasonable alternative, providing convenience, low cost, and ease of use while still maintaining a satisfactory recovery rate of N. gonorrhoeae from clinical specimens, if specimens can be inoculated onto selective media within a relatively short time period not involving overnight shipment.
منابع مشابه
Comparison of Easy-Flow Copan Liquid Stuart's and Starplex Swab transport systems for recovery of fastidious aerobic bacteria.
Because samples are frequently submitted on swabs from distant sites, viability of the organism must be maintained. We compared two transport systems, a new Copan Liquid Stuart's swab with an Easy-Flow swab applicator and the Starplex Liquid Stuart's swab. The purpose of the study was to assess the release and/or recovery of organisms from the Copan system compared to that from Starplex. Tripli...
متن کاملEvaluation of COBAS AMPLICOR (Roche): accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens.
We evaluated further the accuracy of the COBAS AMPLICOR (Roche) (CA) PCR-based system in detection of Chlamydia trachomatis and Neisseria gonorrhoeae in endocervical specimens. Endocervical specimens collected for any indication for testing for C. trachomatis and N. gonorrhoeae among a university hospital health system population were included. Testing for C. trachomatis was done by two PCR met...
متن کاملComparison of commercial Amies transport systems with in-house Amies medium for recovery of Neisseria gonorrhoeae.
Microbiologists are still encumbered by the variable performance of Amies charcoal transport medium in recovery of Neisseria gonorrhoeae. The objective of this study was to evaluate and select a good quality commercial system to replace our in-house preparation. We adsorbed 0.1 ml of a suspension from 30 gonococcal isolates onto each swab type and replaced the swab into the transport medium. We...
متن کاملDetection of Neisseria gonorrhoeae and Chlamydia trachomatis in genitourinary specimens from men and women by a coamplification PCR assay.
A coamplification PCR test for the direct detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urethral and endocervical swabs and urine samples from men and women was compared to standard culture techniques. Processed specimens were amplified in single reaction tubes containing primers for both organisms, and PCR products were detected by a colorimetric microwell plate hybridization...
متن کاملEvaluation of the abbott LCx assay for detection of Neisseria gonorrhoeae in endocervical swab specimens from females.
The Abbott LCx Neisseria gonorrhoeae assay (Abbott Laboratories, Abbott Park, Ill.) uses a ligase chain reaction (LCR) amplification in the LCx probe system for detection of a specific nucleotide sequence in the Opa-encoding gene of N. gonorrhoeae. We evaluated the LCx assay in a comparison with conventional culture employing modified Thayer-Martin media for the detection of N. gonorrhoeae from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 11 شماره
صفحات -
تاریخ انتشار 1999