CLINICAL APPLICATIONS Capillary Electrophoresis

نویسنده

  • P. G. Righetti
چکیده

Column Zorbax silica, 25 cm 4.6 mm internal diameter (7 m) S5W uncoated silica, 25 cm 4.6 mm internal diameter (5 m) Eluent Hexane}ethyl acetate, 95 : 5 CO2 modified with small amounts of methanol Flow rate 1.6 mL min 1 2 mL min 1 for 4 min, then gradient of 2 up to 5 mL min 1 thereafter held constant Programme Isocratic P"100 atm, T"403C; modifier, 1.5%min 1 from 10% to 30% thereafter held constant Injected amount 20 L of a 5% solution of oil in ethyl acetate 100 L of a solution obtained by diluting 0.71 g of oil to 20 mL of ethyl acetate Detection UV absorbance at 315 nm UV absorbance at 315 nm

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical analysis by microchip capillary electrophoresis.

Clinical analysis often requires rapid, automated, and high-throughput analytical systems. Microchip capillary electrophoresis (CE) has the potential to achieve very rapid analysis (typically seconds), easy integration of multiple analytical steps, and parallel operation. Although it is currently still in an early stage of development, there are already many reports in the literature describing...

متن کامل

Capillary electrophoresis for short-chain organic acids and inorganic anions in different samples.

This review article is a comprehensive survey of capillary electrophoresis methods developed for the measurement of short-chain organic acids and inorganic anions in a wide variety of matrices, such as food and beverages, environmental, industry, and other applications, as well as clinical applications in body fluids such as urine, plasma or cerebrospinal fluid. Details of sample pretreatment a...

متن کامل

Miniaturized electrophoresis: an evolving role in laboratory medicine.

The promise of capillary electrophoresis (CE) for supplanting conventional methods in the clinical laboratory led to intense interest in this analytical tool a decade ago. Since then, a number of clinical applications have been defined along with those that have impacted the pharmaceutical, environmental, and forensic arenas. Concurrent with the development of CE applications was the emergence ...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003