Redundancies in X-ray images due to the epipolar geometry for transmission imaging

نویسندگان

  • André Aichert
  • Nicole Maass
  • Yu Deuerling-Zheng
  • Martin Berger
  • Michael Manhart
  • Joachim Hornegger
  • Andreas K. Maier
  • Arnd Doerfler
چکیده

In Computer Vision, the term epipolar geometry describes the intrinsic geometry between two pinhole cameras. While the same model applies to X-ray source and detector, the imaging process itself is very different from visible light. This paper illustrates the epipolar geometry for transmission imaging and makes the connection to Grangeat’s theorem, establishing constraints on redundant projection data along corresponding epipolar lines. Using these redundancies, a geometric consistency metric is derived. Our metric could be applied to any pair of transmission images and could be used for pose refinement, calibration correction and rigid motion estimation in fluoroscopy and flat detector computed tomography (FD-CT) . In addition to the theoretical contribution, this paper investigates the properties and behavior of the metric for the purpose of re-calibration of an FD-CT short scan for narrow angular range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epipolar Consistency in Fluoroscopy for Image-Based Tracking

Geometry and physics of absorption imaging impose certain constraints on X-ray projections. Recently, the Epipolar Consistency Conditions (ECC) have been introduced and applied to motion correction in flat-detector computed tomography (CT). They are based on redundant information in transmission images along epipolar lines. Unlike other consistency conditions for CT scans, they act directly on ...

متن کامل

Medical Imaging Teacher: A Program to Simulate X-Ray Images of the Body by Considering kVp, mAs, and FFD Values

Introduction: Teaching styles and methods have been constantly changing in the recent years. In the 1980s and 90s, the world was introduced to various developed devices, such as smart boards and early generation smart phones that had an immediate innovative effect on education. These advancements has resulted in a considerable improvement in the current educational techniques. The innovations i...

متن کامل

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014