MO-D-BRB-06: JUNIOR INVESTIGATOR WINNER - Fast and Accurate Patient Specific Collision Detection for Radiation Therapy.

نویسندگان

  • R Cardan
  • R Popple
  • J Duan
  • S Shen
  • X Wu
  • I Brezovich
چکیده

PURPOSE To develop a fast and generalizable method which can identify all possible hardware collisions specific to a given patient setup before treatment planning. METHODS An anthropomorphic phantom placed in a typical breast setup using a wingboard was simulated on a CT scanner and the phantom body contour, table, and gantry geometry were made into polygon meshes using 3D modeling software. In the treatment room, a limited physical search of the collision positive zones was performed using the positioned phantom. A software tool that incorporated a generalized hierarchical bounding box (HBB) collision detection algorithm was developed and used to virtually map out the entire collision space by transforming the positions of the polygonal geometry over a given parameter range. RESULTS The geometry containing 47K polygons was mapped over a space of 6480 states with an average transform/collision check of 5.5ms, for a total time of 35.6s on a 3.14GHz dual core computer with 4GB memory. The computed collision space, using receiver operating curve analysis had an accuracy of 96.35%, and a positive predictive value of 91.2%. CONCLUSIONS This work demonstrates a framework that can provide a fast and accurate map of the collision free space specific to any patient setup. Differences in physical and simulated collision space is attributed to inaccuracies of the geometrical models used. Future work includes improving the efficiency of the algorithm, enhancing the geometrical models and increasing the dimensions of the search.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج یک کُد فرترن برای محاسبه دوز غده‌ای در ماموگرافی با استفاده از پارامترهای Sobol-Wu

Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...

متن کامل

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

Comprehensive 3D Visual Simulation for Radiation Therapy Planning

External beam radiation therapy is concerned with the precise and accurate delivery of radiation for cancer treatment. Highly-collimated beams are generated in a linear accelerator, consisting of several hardware components that move around the patient in a complex geometry to allow radiation target the tumor from every possible angle. The complex arrangements of the hardware components may giv...

متن کامل

Making a novel method to obtain the required irradiation time in fast neutron radiation therapy of liver tissue

During radiotherapy by any radiation, it is always essential to stop absorbing the excess dose by a tissue. To better treat cancerous tissues and to make more precise irradiation for a cancerous tumor, there needs the accurate irradiation time to be estimated. First, the constituent materials of any of the existing organs in abdominal tissue are extracted and defined in the MCNPX code. Then, ev...

متن کامل

An Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method

Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part21  شماره 

صفحات  -

تاریخ انتشار 2012