Novel method for measuring effects of gas compression on expiratory flow.
نویسندگان
چکیده
During forced vital capacity maneuvers in subjects with expiratory flow limitation, lung volume decreases during expiration both by air flowing out of the lung (i.e., exhaled volume) and by compression of gas within the thorax. As a result, a flow-volume loop generated by using exhaled volume is not representative of the actual flow-volume relationship. We present a novel method to take into account the effects of gas compression on flow and volume in the first second of a forced expiratory maneuver (FEV(1)). In addition to oral and esophageal pressures, we measured flow and volume simultaneously using a volume-displacement plethysmograph and a pneumotachograph in normal subjects and patients with expiratory flow limitation. Expiratory flow vs. plethysmograph volume signals was used to generate a flow-volume loop. Specialized software was developed to estimate FEV(1) corrected for gas compression (NFEV(1)). We measured reproducibility of NFEV(1) in repeated maneuvers within the same session and over a 6-mo interval in patients with chronic obstructive pulmonary disease. Our results demonstrate that NFEV(1) significantly correlated with FEV(1), peak expiratory flow, lung expiratory resistance, and total lung capacity. During intrasession, maneuvers with the highest and lowest FEV(1) showed significant statistical difference in mean FEV(1) (P < 0.005), whereas NFEV(1) from the same maneuvers were not significantly different from each other (P > 0.05). Furthermore, variability of NFEV(1) measurements over 6 mo was <5%. We concluded that our method reliably measures the effect of gas compression on expiratory flow.
منابع مشابه
Innovative Methodology Novel method for measuring effects of gas compression on expiratory flow
Sharafkhaneh, Amir, Todd M. Officer, Sheila GoodnightWhite, Joseph R. Rodarte, and Aladin M. Boriek. Novel method for measuring effects of gas compression on expiratory flow. Am J Physiol Regul Integr Comp Physiol 287: R479–R484, 2004. First published April 29, 2004; 10.1152/ajpregu.00573.2003.—During forced vital capacity maneuvers in subjects with expiratory flow limitation, lung volume decre...
متن کاملMethod to produce American Thoracic Society flow-time waveforms using a mechanical pump.
The American Thoracic Society (ATS) recently adopted a new set of 26 standard flow-time waveforms for use in testing both diagnostic and monitoring devices. Some of these waveforms have a higher frequency content than present in the ATS-24 standard volume-time waveforms, which, when produced by a mechanical pump, may result in a pump flow output that is less than the desired flow due to gas com...
متن کاملPeak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملAdvanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...
متن کاملتأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی
Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Regulatory, integrative and comparative physiology
دوره 287 2 شماره
صفحات -
تاریخ انتشار 2004