Are Standard Intra-Abdominal Pressure Values Different during Pregnancy?

نویسندگان

  • Florent Fuchs
  • Marie Bruyere
  • Marie-Victoire Senat
  • Emilien Purenne
  • Dan Benhamou
  • Hervé Fernandez
چکیده

BACKGROUND Measurement of intra-abdominal pressure (IAP) is an important parameter in the surveillance of intensive care unit patients. Standard values of IAP during pregnancy have not been well defined. The aim of this study was to assess IAP values in pregnant women before and after cesarean delivery. METHODS This prospective study, carried out from January to December 2011 in a French tertiary care centre, included women with an uneventful pregnancy undergoing elective cesarean delivery at term. IAP was measured through a Foley catheter inserted in the bladder under spinal anaesthesia before cesarean delivery, and every 30 minutes during the first two hours in the immediate postoperative period. RESULTS The study included 70 women. Mean IAP before cesarean delivery was 14.2 mmHg (95%CI: 6.3-23). This value was significantly higher than in the postoperative period: 11.5 mmHg (95%CI: 5-19.7) for the first measurement (p = 0.002). IAP did not significantly change during the following two postoperative hours (p = 0.2). Obese patients (n = 25) had a preoperative IAP value significantly higher than non-obese patients: 15.7 vs. 12.4; p = 0.02. CONCLUSION In term pregnancies, IAP values are significantly higher before delivery than in the post-partum period, where IAP values remain elevated for at least two hours at the level of postoperative classical abdominal surgery. The knowledge of these physiological changes in IAP values may help prevent organ dysfunction/failure when abdominal compartment syndrome occurs after cesarean delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review

The last several decades have seen many advances in the recognition and prevention of the abdominal compartment syndrome (ACS) and its precursor, intra-abdominal hypertension (IAH). There has also been a relative explosion of knowledge in the critical care, trauma, and surgical populations, and the inception of a society dedicated to its understanding, the World Society of the Abdominal Compart...

متن کامل

Intra-abdominal pressure in third trimester pregnancy complicated by acute pancreatitis: an observational study

BACKGROUND It is known that intra-abdominal hypertension has high morbidity in acute pancreatitis and has detrimental effects on patients. For third trimester pregnancy complicated by acute pancreatitis, the intra-abdominal pressure may have its own characteristic. This article will discuss this clinical scenario. METHODS This observational study in a cohort group was performed in the surgica...

متن کامل

Assessment of fluid responsiveness during increased intra-abdominal pressure: keep the indices, but change the thresholds

Dynamic variables of fluid responsiveness are useful guides for fluid management in patients under controlled positive pressure ventilation. In the previous issue of Critical Care, Jacques and colleagues show that these variables remain reliable predictors of fluid responsiveness in a porcine model of intra-abdominal hypertension, but threshold values are higher than during normal intra-abdomin...

متن کامل

Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma

Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...

متن کامل

ارتباط بین فشار داخل شکمی و عوارض حول و حوش جراحی

Background and Aim: Intra-abdominal pressure, (IAP), is the pressure inside the abdominal cavity. Its normal value has not been defined clearly, but it may range from sub-atmospheric to about 7 mmHg. Intra-abdominal hypertension, defined as IAP greater than 12 mmHg, has been reported in critically ill patients and is associated with cardio-respiratory and renal co-morbidities. The effect of bor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013