Apical extrusion of debris using ProTaper Universal and ProTaper Next rotary systems.

نویسندگان

  • M M Koçak
  • E Çiçek
  • S Koçak
  • B C Sağlam
  • N Yılmaz
چکیده

AIM To assess and compare the amount of extruded debris after canal preparation using ProTaper Universal and ProTaper Next files. METHODOLOGY Forty extracted mandibular premolars with single canals and of similar lengths were instrumented using the ProTaper Universal F3 or the ProTaper Next X3. The extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were stored in an incubator for 5 days. The tubes were weighed to obtain the final dry weight of the extruded debris. The amount of apically extruded debris was calculated by subtracting the initial weight of the tube from the final weight. The distribution of the data was examined using the Shapiro-Wilks test. Continuous variables were compared with an independent-samples t-test for two groups. RESULTS All specimens were associated with apical debris extrusion. The ProTaper Universal group produced a significantly greater amount of debris extrusion (P < 0.001). The lowest and highest amounts of debris for PTU and PTN groups were recorded as 0.00117-0.00165 g and 0.00017-0.00067 g, respectively. CONCLUSION ProTaper Next files was associated with significantly less extruded apical debris when compared to ProTaper Universal files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis

BACKGROUND All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. OBJECTIVES Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), an...

متن کامل

An in vitro comparison of apically extruded debris and instrumentation times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex instruments.

INTRODUCTION The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. METHODS Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Co...

متن کامل

Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

OBJECTIVE The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. MATERIAL AND METHODS The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Univ...

متن کامل

Comparison of Apical Extrusion of Debris by Using Single-File, Full-Sequence Rotary and Reciprocating Systems

OBJECTIVES During root canal preparation, apical extrusion of debris can cause inflammation, flare-ups, and delayed healing. Therefore, instrumentation techniques that cause the least extrusion of debris are desirable. This study aimed to compare apical extrusion of debris by five single-file, full-sequence rotary and reciprocating systems. MATERIALS AND METHODS One hundred twenty human mandi...

متن کامل

Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

BACKGROUND Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. AIM The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. DESIGN E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2015