Liquid scintillation counting of (3H) and (14C) on solid supports: a warning.

نویسندگان

  • E D Bransome
  • M F Grower
چکیده

Liquid scintillation counting of (3H) and (‘“C) -labeled compounds on solid supports is a common practice in biochemistry. Furlong has recently emphasized “local quenching” of tritium by filter paper, and has suggested that p’s of higher energy might also be anomalously absorbed if they penetrated under the surface of a filter paper support (1, 2). It is the purpose of this report to show that such local “selfabsorption” occurs when (%)-labeled small molecules are counted on various solid supports. The losses of (‘“C) efficiency, although not as profound as those of (3H), are very significant when (‘“C) discrimination settings for double-isotope counting are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

Sample preparation for quantitation of tritium by accelerator mass spectrometry.

The capability to prepare samples accurately and reproducibly for analysis of tritium (3H) content by accelerator mass spectrometry (AMS) greatly facilitates isotopic tracer studies in which attomole levels of 3H can be measured in milligram-sized samples. A method has been developed to convert the hydrogen of organic samples to a solid, titanium hydride, which can be analyzed by AMS. Using a t...

متن کامل

Comparison of the efficacy of biodegradable and non-biodegradable scintillation liquids on the counting of tritium- and [14C]-labeled compounds.

The widespread use of H and 14C in research has generated a large volume of waste mixed with scintillation liquid, requiring an effective control and appropriate storage of liquid radioactive waste. In the present study, we compared the efficacy of three commercially available scintillation liquids, Optiphase HiSafe 3, Ultima-Gold AB (biodegradable) and Insta-Gel-XF (non-biodegradable), in term...

متن کامل

Non-cholinergic effects of paraoxon on [3h]-GABA release from rat cerebellar giant synaptosomes

Diethyl p-nitrophenyl phosphate (paraoxon) is the active toxic metabolite of parathion. Some evidences indicate that OPs affect the GABA system via noncholinergic mechanisms. The purpose of this study was to investigate the effects of paraoxon on K+-evoked [3H]-GABA release from cerebellar synaptosomes. Adult male rats (200 ± 30 g; 3-4 months old) were sacrificed by decapitation and the cerebel...

متن کامل

Cellular localization of 2-[3H]deoxy-D-glucose from paraffin-embedded brains.

Results of experiments in which regional neuronal activity is revealed by a 2-[3H]deoxy-D-glucose (3H-2-DG)-paraffin section-emulsion autoradiography method are described. The trigeminal pathway of freely behaving mice was activated differentially by selective patterns of whisker removal. One hour after injection of concentrated 3H-2-DG, the animals were perfused systemically with a periodate/l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical biochemistry

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 1970