Frequency of discordance between facet joint activity on technetium Tc99m methylene diphosphonate SPECT/CT and selection for percutaneous treatment at a large multispecialty institution.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The clinical impact of facet joint bone scan activity is not fully understood. The hypothesis of this study is that facet joints targeted for percutaneous treatment in clinical practice differ from those with reported activity on technetium Tc99m methylene diphosphonate SPECT/CT. MATERIALS AND METHODS All patients with a technetium Tc99m methylene diphosphonate SPECT/CT scan of the lumbar or cervical spine who underwent subsequent percutaneous facet joint steroid injection or comparative medial branch blocks at our institution between January 1, 2008, and February 19, 2013, were identified. Facet joints with increased activity were compared with those treated. A chart review characterized the clinical reasons for treatment discrepancies. RESULTS Of 74 patients meeting inclusion criteria, 52 (70%) had discrepant imaging findings and treatment selection of at least 1 facet joint, whereas 34 patients (46%) had a side (right vs left) discrepancy. Only 92 (70%) of 132 facet joints with increased activity were treated, whereas 103 (53%) of 195 of treated facet joints did not have increased activity. The most commonly documented clinical rationale for discrepancy was facet joint activity that was not thought to correlate with clinical findings, cited in 18 (35%) of 52 patients. CONCLUSIONS Facet joints undergoing targeted percutaneous treatment were frequently discordant with those demonstrating increased technetium Tc99m methylene diphosphonate activity identified by SPECT/CT at our institution, in many cases because the active facet joint(s) did not correlate with clinical findings. Further prospective double-blinded investigations of the clinical significance of facet joint activity by use of technetium Tc99m methylene diphosphonate SPECT/CT and comparative medial branch blocks are needed.
منابع مشابه
Increased 99 mTc MDP activity in the costovertebral and costotransverse joints on SPECT - CT : is it predictive of associated back pain or response to percutaneous treatment ? MUSCULOSKELETAL IMAGING
PURPOSE Pain related to costovertebral and costotransverse joints is likely an underrecognized and potentially important cause of thoracic back pain. On combined single-photon emission computed tomography and computed tomography (SPECT-CT), increased technetium-99m methylene diphosphonate (99mTc MDP) activity at these articulations is not uncommon. We evaluated whether this activity corresponds...
متن کاملComparison of facet joint activity on 99mTc-MDP SPECT/CT with facet joint signal change on MRI with fat suppression.
PURPOSE We compared signal change on magnetic resonance imaging (MRI) with fat suppression and bone scan activity of lumbar facet joints to determine if these two imaging findings are correlated. METHODS We retrospectively identified all patients who underwent imaging of the lumbar spine for pain evaluation using both technetium-99m methylene disphosphonate single-photon emission computed tom...
متن کاملSUV measurement of normal vertebrae using SPECT/CT with Tc-99m methylene diphosphonate.
The purpose of this study is to perform quantitative measurement based on the standardized uptake value (SUV) of the uptake of Tc-99m methylene diphosphonate (MDP) in the normal vertebrae using a single photon emission tomography (SPECT)/computed tomography (CT) scanner. A retrospective study of patients with cancer or joint disorders was performed. We acquired data for a group of 29 patients (...
متن کاملTechnetium-99m Methylene Diphosphonate Single-photon Emission Computed Tomography/Computed Tomography of the Foot and Ankle
The complex anatomy and function of the foot and ankle can make it difficult to determine the cause of symptoms in patients with foot and ankle pathology. Following initial clinical and radiographic assessment, additional imaging with magnetic resonance imaging may be required, which is often seen as the modality of choice. Although sensitive to pathological changes in bone metabolism and vascu...
متن کاملThe effect of prednisolone on the sensitivity of Technetium 99m-methylene diphosphonate ( 99m Tc-MDP) scintigraphy to detect simulated closed fracture in the rat tibia
Introduction: The purpose of the present study was to evaluate the effect of prednisolone on the sensitivity of bone scanning to detect the simulated closed fracture in the rat tibia. Methods: A total number of forty eight adult, male NMRI rats randomly assigned into two parts, one part for 4 and other for 8 weeks experiments. Each part has been divided into four groups, one group not receivi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2014