PURPOSE This study was initiated to prove feasibility of hydrogel application in recto-vaginal space in intracavitary brachytherapy (ICBT) of cervical cancer in order to reduce rectal toxicity. MATERIAL AND METHODS In a case of stage IIB cervical cancer, after external beam radiotherapy (EBRT), we planned ICBT 7 Gy × 3 fractions. In 1st fraction (Plan 1), due to narrow separation between rectum and cervix (0.18 cm), only 5 Gy was delivered at point A (with high-risk clinical target volume [HR-CTV] D90 5.94 Gy, intermediate risk clinical target volume [IR-CTV] D90 4.54 Gy, rectum D2cc 5.72 Gy, bladder D2cc 5.52 Gy, and sigmoid colon 5.82 Gy). In 2nd fraction (Plan 2), interstitial brachytherapy (ISBT) was attempted. For the prescription of 5 Gy, we get dose levels almost similar to the 1st insertion: HR-CTV D90 (6.7 Gy), IR-CTV D90 (3.06 Gy), bladder D2cc (5.7 Gy), rectum D2cc (4.8 Gy), sigmoid colon D2cc (1.3 Gy) (separation = 0.23 cm). During 3rd fraction (Plan 3), prior doing interstitial insertion, we instilled 50 cc of hydroxypropyl methylcellulose (Viscomet®) up to the tip of recto-vaginal septum. A repeat computed tomography (CT) scan was done 4 hours after Plan 3 treatment and it was re-planned (Plan 4) to find out migration of hydrogel if any and its dosimetric impact. RESULTS 9 Gy was delivered to point A with a separation of 1.1 cm in Plan 3 (with HR-CTV D90 16.4 Gy, IR-CTV D90 11.3 Gy, rectum D2cc 3.6 Gy, bladder D2cc 6.9 Gy, and sigmoid colon 2.2 Gy). We achieved an optimum cumulative EQD2 dose (HR-CTV D90 98.4 Gy, IR-CTV D90 76.1 Gy, rectum D2cc 67.7 Gy, bladder D2cc 73.2 Gy, and sigmoid colon 59.3 Gy). Hydrogel volume was decreased in Plan 4 without a major dosimetric changes. CONCLUSIONS Hydrogel instillation is a useful tool for recto-vaginal separation during cervical cancer brachytherapy. It increases therapeutic ratio without any adverse event.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations

Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...

متن کامل

The rectum and bladder doses in intracavitary brachytherapy for cervical cancer

PURPOSE The aim of this work was to study the International Commission on Radiation Unit and Measurement (ICRU) for rectum (rICRU) and bladder (bICRU) dose behaviors in the treatment of cervical cancer by high dose rate (HDR) intracavitary brachytherapy (ICRT). MATERIAL AND METHODS A retrospective study was carried out on 38 patients with a total of 38 fractions (1st fraction of each patient)...

متن کامل

The usefulness of fleet rectal enemas on high-dose-rate intracavitary cervical cancer brachytherapy. A prospective trial

PURPOSE To evaluate the effects of rectal enemas on rectal doses during radical high-dose-rate (HDR) intracavitary cervical brachytherapy (BT). MATERIAL AND METHODS Twenty patients suffering from cervical cancer and treated with external beam radiotherapy and HDR-BT were included in a prospective trial. The first brachytherapy fraction was considered the basal status, and patients were instru...

متن کامل

Non isocentric film-based intracavitary brachytherapy planning in cervical cancer: a retrospective dosimetric analysis with CT planning

PURPOSE To compare intracavitary brachytherapy dose estimation for organs at risk (bladder and rectum) based on semi-orthogonal reconstruction of radiographs on non-isocentric X-ray unit and Computed Tomography (CT) - based volumetric planning in cervical cancer. MATERIAL AND METHODS Bladder and rectal points as per International Commission on Radiation Units and Measurements (ICRU) report 38...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016