A high-resolution computed tomographic study of changes in root canal isthmus area by instrumentation and root filling.

نویسندگان

  • Unni Endal
  • Ya Shen
  • Arving Knut
  • Yuan Gao
  • Markus Haapasalo
چکیده

INTRODUCTION The aim of this study was to obtain a three-dimensional analysis of the isthmus area of the mesiobuccal root canal system in mandibular molars using high-resolution micro-computed tomography (μ-CT) scanning and to measure the amount of debris and root filling material in the isthmus after instrumentation/irrigation and root filling. METHODS Mandibular molars with two separated mesial root canals (10 teeth) were scanned by using the Skyscan 1172 μ-CT system (Skyscan, Aartselaar, Belgium) before and after instrumentation and after filling using the Thermafil root filling technique. An isthmus was defined as the ribbon-shaped or thin connecting structure between two root canals after instrumentation. The characteristics of the isthmuses were quantitatively monitored during the whole treatment. The images were segmented and quantified. The surface area of the isthmus, volume of debris after rotary instrumentation, and volume of the filled space in the isthmus after obturation were evaluated. RESULTS Of the seven mesial roots, two had isthmus/anastomoses somewhere along its length in the apical 5 mm, and five had an isthmus that was continuous all the way from the coronal part to the apical part. The average percentage of isthmus surface area and isthmus volume after instrumentation was 21.4% and 9.4% of the whole root canal system, respectively. About 35.2% of the isthmus volume was filled with apparent hard tissue debris after instrumentation/irrigation. The average percentage of volume of filling material in the isthmus areas was significantly lower (57.5%) than in the main root canals (98.5%, p < 0.001). CONCLUSIONS A considerable amount of dentin debris is produced and packed into the isthmus area during rotary instrumentation of mesial canals of lower molars despite continuous irrigation during and after instrumentation. The debris may partly prevent penetration of the filling material and sealer into the isthmus area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

The quality of root canal preparation and root canal obturation in canals treated with rotary versus self-adjusting files: a three-dimensional micro-computed tomographic study.

AIM The study was designed to quantitatively evaluate the quality of root canal preparation and root canal obturation in canals treated with either rotary or self adjusting files, using three-dimensional micro-computed tomographic (CT) analysis. METHODOLOGY Pair-matched root canals were instrumented with either rotary nickel-titanium files or self-adjusting files following the manufacturers' ...

متن کامل

Evaluation of Root Canal Transportation using Bio Race and K -Flexo file instruments: using cone-Bean Computed

Background & Aim: Deviation from the original shape of the canal leads to poor filling and lack of proper canal seal and consequently to the failure of root treatment The aim of this experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and BioRace rotary instruments by cone-beam computed tomography (CBCT). Material and Methods: In t...

متن کامل

Micro-computed tomographic evaluation of canal retreatments performed by undergraduate students using different techniques

Objectives This study evaluated the amount of remaining root canal filling materials after retreatment procedures performed by undergraduate students using manual, rotary, and reciprocating techniques through micro-computed tomographic analysis. The incidence of instrument fracture and the instrumentation time were also evaluated. Materials and Methods Thirty maxillary single rooted teeth wer...

متن کامل

An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography

Background and purpose: The purpose of mechanical cleaning of the root canal is to clean the canal walls, create a conical shape to facilitate access, effective washing, and filling all areas of the root canal. Errors such as root canal transportation are cuased by excessive dentin removal from the canal. The objective of this study was to investigate root canal transportation by a BT Race rota...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2011