Electron Trapping Variations in Single-Crystal Pixelated HgI2 Gamma-Ray Spectrometers

نویسنده

  • J. E. Baciak
چکیده

The characteristics of thick ( 6 mm) HgI 2 room-temperature gamma-ray detectors having 4 small pixel anodes are investigated. Spectra for the different anodes (overall and for individual interaction depths) are presented. The mu–tau product for electrons was measured to study the variations of electron transport within a single HgI 2 crystal. By using the single polarity charge sensing with depth sensing, the was estimated to vary from 9 10 4 cm V to 7 10 3 cm V. Individual pixels have the ability to produce spectra with resolutions less than 3% at 662 keV. Some effects of electron detrapping and hole transport are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 5 and 10mm thick HgI2 pixelated g-ray spectrometers

HgI2 detectors fabricated with pixelated anodes were tested as potential room temperature spectrometers. Spectra were obtained with 5 and 10mm thick devices, and their results were compared. The 5mm thick devices showed some effect of the anode weighting potential, while the 10mm thick devices showed the effects of charge diffusion/sharing and electron trapping. A resolution near 1.4% FWHM usin...

متن کامل

Spectroscopy on Thick HgI2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Thick mercuric iodide (HgI 2 ) detectors are investigated as potential room temperature gamma-ray spectrometers. By using pixelated anodes the induced charge on the electrode is dependent mainly on electron movement and is almost independent of the depth of interaction. Moreover, by reading out the planar cathode signal simultaneously, the depth of interaction can be determined and any effects ...

متن کامل

3D position sensitive CdZnTe gamma-ray spectrometers – improved performance with new ASICs

A 3-dimensional position sensitive CdZnTe gamma-ray spectrometer based on VAS3.1/TAT3 ASICs was developed and tested. The 3-D CZT spectrometer employs a 1.5 × 1.5 × 1 cm CdZnTe crystal with 11 by 11 pixelated anodes wire-bonded to the readout electronics. The signals from the anode pixels and the cathode were both read out through the ASICs. The pixel position provides the lateral 2-D coordinat...

متن کامل

Large Volume HgI2 Gamma-Ray Spectrometers

This paper demonstrates the enhanced capability of single polarity charge sensing, the 3-dimensional position sensing technique, developed at the University of Michigan and previously successfully demonstrated on CdZnTe detectors, to improve the spectroscopic performance of HgI2 and to extend its range for spectrometry to an unprecedented thickness of 10 mm. Energy resolutions of close to 1% FW...

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001