Comparison of a polymer conjugate-enhanced enzyme immunoassay to ligase chain reaction for diagnosis of Chlamydia trachomatis in endocervical swabs.

نویسندگان

  • M Chernesky
  • D Jang
  • D Copes
  • J Patel
  • A Petrich
  • K Biers
  • A Sproston
  • J Kapala
چکیده

Two endocervical swabs from each of 1,123 women were collected into manufacturer-supplied transport tubes and tested for Chlamydia trachomatis by a polymer conjugate-enhanced (PCE) enzyme immunoassay (EIA) (IDEIA PCE Chlamydia; DAKO) and a ligase chain reaction assay (LCx Chlamydia; Abbott). After confirmation by the EIA blocking test, the sensitivity of the IDEIA PCE remained at 91.8% and the specificity increased from 98.2 to 99.8% compared to LCx.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens.

AIMS To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. METHODS Two population groups were tested. For the first population gro...

متن کامل

Evaluation of near patient testing for Chlamydia trachomatis in a pregnancy termination service.

AIM To identify and evaluate advantages and disadvantages of a near patient test (NPT) for Chlamydia trachomatis, using Clearview Chlamydia MF (Unipath Ltd) in a British Pregnancy Advisory Service (BPAS) clinic. METHOD The improved Clearview Chlamydia MF test was used to test endocervical swabs from 400 women attending BPAS clinic for termination of pregnancy. The results were compared with L...

متن کامل

Chlamydia trachomatis load at matched anatomic sites: implications for screening strategies.

Urethral and endocervical swabs and self-collected vaginal swabs (SCVSs) and urine specimens are all used as samples for diagnosis of urogenital infection with Chlamydia trachomatis. We have now determined chlamydial organism load in matched specimens from different anatomic sites and examined its relation to clinical signs and symptoms in men and women. Organism load was measured with assays b...

متن کامل

Pooling cervical swabs and testing by ligase chain reaction are accurate and cost-saving strategies for diagnosis of Chlamydia trachomatis.

Specimen pooling to achieve efficiency when testing urine specimens for Chlamydia trachomatis nucleic acids has been suggested. We pooled endocervical swabs from 1,288 women and also tested individual swabs by ligase chain reaction (LCR). Out of 53 positive specimens, pools of 4 or 8 specimens missed two positives, providing 96.2% accuracy compared to individual test results. Dilution and posit...

متن کامل

Lowering the cut off value of an automated chlamydia enzyme immunoassay and confirmation by PCR and direct immunofluorescent antibody test.

AIMS To increase the sensitivity of an automated chlamydia enzyme immunoassay by significantly lowering its cut off value, and to maintain specificity by confirmation with polymerase chain reaction (PCR) and direct immunofluorescent antibody test (DFA). METHODS Over five months, the cut off value of the enzyme immunoassay used to screen urogenital samples for chlamydia antigen was reduced fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 2001