ar X iv : a st ro - p h / 05 06 28 8 v 1 1 3 Ju n 20 05 A Deep Infrared Search for AXP 1 E 1841 − 045

نویسنده

  • Martin Durant
چکیده

Multi-colour (JHKS) imaging and photometry of the field of the Anomalous X-ray Pulsar AXP 1E 1841−045 is analysed in the light of new, accurate coordinates from Chandra (Wachter et al, 2004). From excellent quality images, we find multiple sources in and around the position error circle. Of these, none can be confidently identified as the infrared counterpart. The limiting magnitudes reached were J = 22.1, H = 20.7 and KS = 19.9 (95% confidence). Subject headings: pulsars: individual (1E 1841-045)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 05 06 29 8 v 1 1 4 Ju n 20 05 The application of slim disk models to ULX : the case of M 33 X - 8

A comparative XMM-Newton archival data spectral study of the ultraluminous Xray source (ULX) M33 X-8 has been performed by using both the standard disk model and the newly developed slim disk models. The results of this analysis tend to confirm the hypothesis that M33 X-8 is an X-ray binary with a stellar-mass black hole accreting at super-Eddington rate.

متن کامل

ar X iv : a st ro - p h / 97 06 05 8 v 1 6 J un 1 99 7 The Discovery of an Anomalous X - ray Pulsar in the Supernova Remnant Kes 73

We report the discovery of pulsed X-ray emission from the compact source 1E 1841−045, using data obtained with the Advanced Satellite for Cosmology and Astrophysics. The X-ray source is located in the center of the small-diameter supernova remnant (SNR) Kes73 and is very likely to be the compact stellar-remnant of the supernova which formed Kes73. The X-rays are pulsed with a period of ≃ 11.8 s...

متن کامل

ar X iv : a st ro - p h / 05 06 26 1 v 1 1 3 Ju n 20 05 Laboratory simulation of cometary x rays using a high - resolution microcalorimeter

X-ray emission following charge exchange has been studied on the University of California Lawrence Livermore National Laboratory electron beam ion traps EBITI and EBIT-II using a high-resolution microcalorimeter. The measured spectra include the K-shell emission from hydrogenlike and heliumlike C, N, O, and Ne needed for simulations of cometary x-ray emission. A comparison of the spectra produc...

متن کامل

ar X iv : a st ro - p h / 06 05 33 0 v 1 1 2 M ay 2 00 6 The infrared counterpart to the magnetar 1 RXS J 170849 . 0 − 400910

We have analyzed both archival and new infrared imaging observations of the field of the Anomalous X-ray Pulsar 1RXS J170849.0−400910, in search of the infrared counterpart. This field has been previously investigated, and one of the sources consistent with the position of the AXP suggested as the counterpart. We, however, find that this object is more likely a background star, while another ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005