Static Analysis of Masonry Infilled R.C.Frame With &Without Opening Including Soft Storey of Symmetric Building
نویسندگان
چکیده
Abstract: Masonry infill is considered as a non-structural element in all type of buildings where masonry use. But, masonry infill walls are mainly used to increase initial stiffness and strength of reinforced concrete (RC) frame buildings. This Open First storey is also termed as “Soft Storey”. The upper storeys have brick infilled wall panels with various opening percentage in it. In many cities of India, it is very common to leave the first storey of masonry infilled reinforcement concrete (RC) frame building open preliminary to generate parking space or any other usage in the first storey. Such buildings are highly undesirable in seismically active areas. In the present study, it is an attempt to access the performance of masonry infilled reinforced concrete (RC) frames with soft storey of with and without opening. In this paper, symmetrical frame of college building (G+5) located in seismic zone-III is considered by modelling of initial frame. According to FEMA-273, & ATC-40 which contain the provisions of calculation of stiffness of infilled frames by modelling infill as“Equivalent Diagonal Strut Method”. Therefore, the infill panels are modelled as equivalent diagonal strut method. The error involved in modelling such buildings as neglecting the presence of infills in the upper storeys, is brought out through the study of an example building with different analytical models. This linear static analysis is to be carried out on the models such as Strut frame with 15%, 20%, & 25% centre &corner opening, which is performed by using computer software STAAD-Pro from which different parameters are computed. In which it shows that how infill panels increase the stiffness of the structure. While the increase in the opening percentage leads to a decrease on the lateral stiffness of infilled frame. This paper highlights the importance of the presence of the open first storey in the analysis of the building.
منابع مشابه
Analysis of Masonry Infilled R.C.Frame with & without Opening Including Soft Storey by using “Equivalent Diagonal Strut Method”
Infilled frame structures are commonly used in buildings. Masonry infilled RC frames are the most common type of structures used for multi-storeyed constructions in the developing countries, even in those which are located in seismically active regions also. Masonry infill walls are mainly used to increase initial stiffness and strength of reinforced concrete (RC) frame buildings. In the presen...
متن کاملSeismic Performance of Reinforced Concrete Frames Infilled by Masonry Walls with Different Heights
This study carried out comparative seismic performance of reinforced concrete frames infilled by masonry walls with different heights. Partial and fully infilled reinforced concrete frames were modeled for the research objectives and the analysis model for a bare reinforced concrete frame was also established for comparison. Non–linear static analyses for the studied frames were performed to in...
متن کاملAssessment of Masonry Infilled Reinforced-concrete Frames with Openings
Original scientific paper Reinforced-concrete (R/C) frames infilled with masonry wall, especially with the presence of an opening, are insufficiently explored structural elements. We have experimentally investigated influence of the opening’s type and position to the lateral response of reinforced-concrete frames with masonry infill. Correction factors, that take into account influence of the o...
متن کاملPerformance Based Seismic Retrofit of Masonry Infilled Reinforced Concrete Frames Using Passive Energy Dissipation Devices
The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at t...
متن کاملAssessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches
Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models us...
متن کامل