A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis.

نویسندگان

  • C J Zeitlin
  • K A Frankel
  • W Gong
  • L Heilbronn
  • E J Lampo
  • R Leres
  • J Miller
  • W Schimmerling
چکیده

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

منابع مشابه

Diamond Detectors for Longitudinal Properties of Pulsed Heavy-Ion Beams

For the investigation of the dynamics of heavy-ion beams penetrating hot dense plasma at the Z6 area at GSI an experimental setup was developed, which allows for diagnosing a directly laser-heated plasma target, and measuring the charge state and energy loss of an ion beam after / in it [1, 2]. The varying energy loss of the ion beam in the target (solid—plasma—vacuum) is determined in a TOFlik...

متن کامل

Measurement of stereotactic beam data of 9 MV X-rays using diode detector

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

متن کامل

The RHIC Zero Degree Calorimeters

High Energy collisions of nuclei usually lead to the emission of evaporation neutrons from both “beam” and “target” nuclei. At the RHIC heavy ion collider with 100GeV/u beam energy, evaporation neutrons diverge by less than 2 milliradians from the beam axis. Neutral beam fragments can be detected downstream of RHIC ion collisions (and a large aperture Accelerator dipole magnet) if θ ≤ 4 mr but ...

متن کامل

Investigation of surface and buildup region doses for 6 MV high energy photon beams in the presence of a thermoplastic mask

Background: The accuracy and the reproducibility of radiotherapy can be provided by using immobilization devices such as thermoplastic masks. In head and neck cancer radiotherapy, the patients are mostly immobilized by using thermoplastic masks. In this study, the effect of the thermoplastic mask to the surface and buildup region doses was investigated by using Markus parallel plate ion chamber...

متن کامل

3-d Measurement of the Nscl Position-sensitive Gamma Ray Detector Array

The National Superconducting Cyclotron Laboratory (NSCL) is a national nuclear physics research laboratory on the campus of Michigan State University. In a typical experiment, heavy ions with masses ranging from hydrogen to uranium are created in an Electron Cyclotron Resonance (ECR) ion source and injected into the K500 cyclotron. The accelerated beam is transported to the K1200 cyclotron, whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Radiation measurements

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 1994