MR Visualization of Spinal Dural Arterio-Venous Fistula Using T2-Weighted 3D SPACE—A Spin-Echo Technique
نویسندگان
چکیده
Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We report on a 56-year-old male patient with progressive neurological symptoms. Preand post-contrast MR imaging of the spine, including contrast-enhanced MR angiography was done on a 1.5 T MR scanner. In addition a special (pre-contrast) 3D turbo-spin-echo sequence with variable flip angle evolution (SPACE) was performed providing a slice thickness of 0.9 mm. T2-weighted images showed extensive widened and tortuous vascular structures with typical flow voids intradurally due to dilated pial veins. The origin of the spinal dural arteriovenous fistula was found to be the radiculomeningeal artery at level D10/11 on the left side, visualized by the T2-weighted 3D SPACE sequence and CE MRA. After imaging the patient was referred to an interventional neuroradiology department for therapy. With the detailed information from MR imaging concerning the fistula level the interventional radiologist was able to find the fistula immediately and consequently treated it successfully by endovascular therapy. Interpreting the MR images of this obvious case of a SDAVF, SPACE sequence after post processing with 3D MPR software directly led to the location of the AV shunt at D10/11 on the left side, better than 3D contrast-enhanced MR angiography did. Therefore, SPACE can be a useful adjunct in further evaluation of spinal dural arteriovenous fistula and especially in defining fistula level.
منابع مشابه
Retrograde cortical and deep venous drainage in patients with intracranial dural arteriovenous fistulas: comparison of MR imaging and angiographic findings.
BACKGROUND AND PURPOSE We assessed MR imaging, specifically contrast-enhanced three-dimensional (3D) magnetization-prepared rapid gradient-echo (MP-RAGE), in evaluating retrograde venous drainage in patients with intracranial dural arteriovenous fistulas (dAVFs) that may result in catastrophic venous infarction or hemorrhage. METHODS Twenty-one patients with angiographically proved dAVFs unde...
متن کاملAssessment of dural arteriovenous fistulas of the cavernous sinuses on 3D dynamic MR angiography.
BACKGROUND AND PURPOSE Flow voids within the cavernous sinuses and/or certain venous drainage on spin-echo MR imaging and time-of-flight (TOF) flow enhancement on MR angiography (MRA) have indicated high-velocity shunt flow and have been used for screening patients with dural arteriovenous fistulas (DAVFs) of the cavernous sinuses. In this investigation, the capabilities of 3D dynamic MRA as a ...
متن کاملSpinal dural arteriovenous fistula : a case report
Background: Spinal dural AVF is the most common type of spinal vascular malformation. However, presenting symptoms differ according to site of spinal involvement. This study described a case of arteriovenous malformation with paraparesis and incontinence. Case Presentation: Diagnosis of patient was confirmed by clinical and imaging examination using magnetic resonance image and ruling out ot...
متن کاملSpinal dural arteriovenous fistulas: evaluation with MR angiography.
PURPOSE To show that postgadolinium three-dimensional time-of-flight MR angiography shows abnormal intradural vessels associated with spinal dural arteriovenous fistula better than routine MR imaging and provides screening information useful for subsequent diagnostic conventional angiography and/or posttreatment evaluation. METHODS Precontrast and postcontrast MR imaging and MR angiograms, as...
متن کاملVisualization of aneurysmal contours and perianeurysmal environment with conventional and transparent 3D MR cisternography.
We have developed conventional and transparent 3D MR cisternography to investigate the spatial relationship between the contours of aneurysmal complex and the perianeurysmal structures including the cranial nerves, dural fold, cranial base bone, and brain parenchyma. Volume data obtained by a T2-weighted 3D fast spin-echo sequence were reconstructed by using a perspective volume-rendering algor...
متن کامل