Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors

نویسندگان

  • Lucas C. Mendez
  • Moti Paudel
  • Matt Wronski
  • Ananth Ravi
  • Lisa Barbera
  • Eric Leung
چکیده

BACKGROUND To evaluate the dosimetric performance of multi-channel vaginal cylinder (MCVC) against interstitial brachytherapy (ISBT) for the treatment of vaginal tumors. METHODS Vaginal tumors with extension of > 0.5 cm and ≤ 2 cm from the lateral vaginal wall and/or ≤ 1 cm in height above the vaginal vault were retrospectively selected from a ISBT registry trial database. The selected patients were treated with ISBT and targets included the intermediate (IRCTV) or high-risk (HRCTV) clinical target volumes. For technique comparison, a 35 mm MCVC was registered with the interstitial intra-vaginal cylinder. Bladder and rectum contours were transferred from the ISBT to the MCVC-BT plans. Vaginal mucosa was achieved by 3 mm uniform expansion from cylinder surface. Both the ISBT and MCVC-BT plans were optimized using the Inverse Planning Simulated Annealing optimization algorithm. After normalizing target D90 to 700 cGy, dose to organs at risk were measured and compared between ISBT and MCVC plans. RESULTS Six interstitial patient plans met the inclusion criteria for this study. Four patients had vaginal primaries and two recurrent cancers in the vagina. Lower doses to bladder and rectum were seen with ISBT plans. In half of the MCVC plans, the rectal dose met the recommended constraints. For plans in which the rectal constraint was not met, the target volumes were abutting the rectum and had a cranial-caudal length ≥ 5 cm. Dose to vaginal mucosa was lower in ISBT plans directed to the HRCTVs, although no difference was seen in circumferential IRCTVs. CONCLUSIONS Overall, ISBT results in decreased dose to OARs as compared to MCVC. However, MCVC BT results in acceptable doses to OARs with possible improvement in vaginal doses for circumferential targets. Careful consideration to tumor geometry and location may help guide optimal techniques in vaginal tumor brachytherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

INTRODUCTION Evaluate use of novel multi-channel applicator (MC) Capri™ to improve vaginal disease coverage achievable by single-channel applicator (SC) and comparable to Syed plan simulation. MATERIALS AND METHODS Twenty-eight plans were evaluated from four patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by three weekly trea...

متن کامل

Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning

PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...

متن کامل

Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators

PURPOSE To retrospectively assess the incidence and magnitude of air pockets around vaginal cylinders and its impact on dose distribution in vaginal cuff image-guided high-dose-rate (HDR) brachytherapy. MATERIAL AND METHODS Fifty endometrial carcinoma patients treated by postoperative HDR vaginal cuff brachytherapy were included in the study. The average age of patients was 58.3 ± 11.8 years ...

متن کامل

Modified Fletcher's 3-channel brachytherapy system with vaginal line source loading versus uterine tandem and vaginal cylinder system in Stage IIIA cervical cancer

PURPOSE The uterine tandem with open-ended vaginal cylinder is the most commonly used brachytherapy system for Federation Internationale de Gynecologie et d'Obstetrique (FIGO) Stage IIIA cervix cancer at the National Cancer Centre, Singapore. Without the 3-channel ovoid system, the dose to the parametrium is often compromised. In this study, a vaginal cylinder that could potentially be incorpor...

متن کامل

Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology

PURPOSE Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS Three brachytherapy patients with unique clinical needs were identified as likely to benefit from a customized vaginal applicator. Pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017