Diffusion-controlled toluene reference material for VOC emissions testing: international interlaboratory study.

نویسندگان

  • Cynthia Howard-Reed
  • Zhe Liu
  • Steven Cox
  • Dennis Leber
  • Dan Samarov
  • John C Little
چکیده

UNLABELLED The measurement of volatile organic compound (VOC) emissions from building products and materials by manufacturers and testing laboratories, and the use of the test results for labeling programs, continue to expand. One issue that hinders wide acceptance for chamber product testing is the lack of a reference material to validate test chamber performance. To meet this need, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) have developed a prototype reference material that emits a single VOC similar to the emissions of a diffusion-controlled building product source with a dynamic emissions profile. The prototype material has undergone extensive testing at NIST and a pilot interlaboratory study (ILS) with four laboratories. The next development step is an evaluation of the prototype source in multiple-sized chambers of 14 laboratories in seven countries. Each laboratory was provided duplicate specimens and a test protocol. Study results identified significant issues related to the need to store the source at a subzero Celsius temperature until tested and possible inconsistencies in large chambers. For laboratories using a small chamber and meeting all the test method criteria, the results were very encouraging with relative standard deviations ranging from 5% to 10% across the laboratories. IMPLICATIONS Currently, the chamber performance of laboratories conducting product VOC emissions testing is assessed through interlaboratory studies (ILS) using a source with an unknown emission rate. As a result, laboratory proficiency can only be based on the mean and standard deviation of emission rates measured by the participating ILS laboratories. A reference material with a known emission rate has the potential to provide an independent assessment of laboratory performance as well as improve the quality of interlaboratory studies. Several international laboratories with different chamber testing systems demonstrated the ability to measure the emission rate of such a reference material within an acceptable measurement uncertainty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion-controlled reference material for VOC emissions testing: proof of concept.

UNLABELLED Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different lab...

متن کامل

Diffusion-controlled reference material for VOC emissions testing: effect of temperature and humidity.

UNLABELLED A polymethylpentene film loaded with toluene is being developed as a reference material to support the reliable measurement of volatile organic compound emissions from building materials using environmental chambers. Earlier studies included the measurement of the material-phase diffusion coefficient (D) and material/air partition coefficient (K) at 23°C. A fundamental mass-transfer ...

متن کامل

Modeling Diffusion-controlled Emissions of Volatile Organic Compounds from Building Materials

The adverse effects of contaminated outdoor air have been recognized and subject to control for many years. More recently environmental engineers and health professionals have become cognizant of the hazards associated with contaminated indoor air. It is now understood that contaminated indoor air negatively impacts human health, worker productivity, and physical property. Volatile organic comp...

متن کامل

Numerical simulation of VOC Emissions from Dry Materials

This paper presents a numerical approach for simulating volatile organic compound (VOC) emissions from dry materials. The approach has been used to examine the VOC emissions from two particleboards. The emission study for the particleboards shows that a fairly good agreement of VOC concentrations between the model prediction and experimental data can be achieved by pre-calculating the partition...

متن کامل

Measurement of volatile organic compounds emitted in libraries and archives: an inferential indicator of paper decay?

BACKGROUND A sampling campaign of indoor air was conducted to assess the typical concentration of indoor air pollutants in 8 National Libraries and Archives across the U.K. and Ireland. At each site, two locations were chosen that contained various objects in the collection (paper, parchment, microfilm, photographic material etc.) and one location was chosen to act as a sampling reference locat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 2014