Analysis of a vertical compliance prosthetic foot.
نویسندگان
چکیده
Mechanical testing of the Re-Flex VSP Foot was conducted on the pylon alone and on the pylon and forefoot system. Values for spring and damping correspond well to values reported in the literature for spring and damping of physiological limbs. Pylon stiffness was 49.4 kN/m for a 600 N subject and 91.4 kN/m for an 800 N subject. The vertical stiffness of the pylon and forefoot together was 31.9 kN/m and 37.8 kN/m, respectively. Gait parameters of two persons with transtibial amputation who used vertically compliant feet for walking, jogging in place, and curb descent were investigated. Ground reaction forces, vertical trunk movement, event timing, and pylon compression were observed. The spring-loaded telescoping pylon was immobilized for half the trials. The trials were repeated the following week with the vertical compliance feature mobilized. Significant differences in vertical trunk motion and timing were found between the prosthetic limb and normal limb, as might be expected. Vertical compliance appeared to cause little change in gait parameters during normal walking. The largest differences appeared during the higher impact events such as fast walking and jogging in place.
منابع مشابه
Biomechanical Analysis of the Influence of SACH Foot and Dynamic-Response Foot in Individual With Unilateral Transtibial Amputee During Running
Objective: Amputation of the lower limb due to loss of part of the musculoskeletal structure reduces performance and increases injury during locomotion. The effect of various types of prosthetic feet has been analyzed in several studies during running. The purpose of this study was a biomechanical analysis of the influence of SACH and Dynamic-Response foot on several kinetic variables in the st...
متن کاملThe effects of prosthetic ankle dorsiflexion and energy return on below-knee amputee leg loading.
BACKGROUND Prosthetic devices are intended to return lower limb amputees to their pre-amputation functional status. However, prosthetic devices designed for unilateral below-knee amputees have yet to completely restore the biomechanical functions normally provided by the ankle muscles, leading to gait asymmetries and increased reliance on their intact leg. In an effort to improve amputee gait, ...
متن کاملThe effect of five prosthetic feet on the gait and loading of the sound limb in dysvascular below-knee amputees.
The purpose of this study was to determine the effects of prosthetic foot design on the vertical ground reaction forces experienced by the sound and amputated limbs in a group of persons with dysvascular below-knee amputations. Stride characteristics, joint motion, and ground reaction forces were recorded simultaneously during a self-selected free walking velocity in seven subjects wearing five...
متن کاملAnalysis of Rollover Shape and Energy Storage and Return in Cantilever Beam-type Prosthetic Feet
This paper presents an analysis of the rollover shape and energy storage and return in a prosthetic foot made from a compliant cantilevered beam. The rollover shape of a prosthetic foot is defined as the path of the center of pressure along the bottom of the foot during stance phase of gait, from heel strike to toe off. This path is rotated into the reference frame of the ankle-knee segment of ...
متن کاملThe influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees.
BACKGROUND Below-knee amputees commonly experience asymmetrical gait patterns and develop comorbidities in their intact and residual legs. Carbon fiber prosthetic feet have been developed to minimize these asymmetries by utilizing elastic energy storage and return to provide body support, forward propulsion and leg swing initiation. However, how prosthetic foot stiffness influences walking char...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 34 1 شماره
صفحات -
تاریخ انتشار 1997