Image quality of digital direct flat-panel mammography versus an analog screen-film technique using a phantom model.

نویسندگان

  • Kathrin Barbara Krug
  • Hartmut Stützer
  • Ralf Girnus
  • Markus Zähringer
  • Axel Gossmann
  • Guido Winnekendonk
  • Klaus Lackner
چکیده

OBJECTIVE The objective of our study was to compare the detection and distinguishability of microcalcifications on mammograms obtained with a digital direct flat-panel detector versus an analog system using an anthropomorphic breast phantom. MATERIALS AND METHODS Studies were performed with a digital mammography system (Selenia) and an analog mammography system (Mammomat 3). Sixty-five transparent films were used as test specimens. Randomly distributed round and heterogeneous silicate particles (diameter, 100-1,400 microm) and an anthropomorphic scatter body were applied to the films. All radiographs were taken at identical settings and exposures. Six radiologists rated the films and monitor-displayed images independently of each other in random order on a standardized electronic questionnaire. RESULTS Interpretations based on monitor reading produced superior results over those based on digital image reading and analog film reading. In 41.1% (95% CI, 38.7-43.5%) of all the monitor readings, 20.2% (18.2-22.2%) of all digital images, and 19.6% (17.6-21.6%) of all analog films, the number of detectable microcalcifications agreed with the gold standard method. The diameter of visible microcalcifications was interpreted correctly in 35.6% (33.2-38.0%) of monitor readings, 19.0% (17.1-21.0%) of digital images, and 21.0% (18.9-23.0%) of analog films; and microcalcification shape was interpreted correctly in 53.8% (51.4-56.3%) of monitor readings, 28.2% (26.0-30.4%) of digital images, and 28.3% (26.0-30.5%) of analog films. Microcalcification number and size were underestimated more frequently than overestimated. Regardless of display medium, accuracy increased proportionately with the diameter of the simulated microcalcifications for all evaluation variables. CONCLUSION Digital flat-panel mammography is superior to the analog screen-film method for the detection and morphologic characterization of microcalcifications larger than 200 microm in diameter when the display medium is a monitor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image Quality of Digital Direct Flat-Panel Mammography Versus an Indirect Small-Field CCD Technique Using a High-Contrast Phantom

OBJECTIVE To compare the detection of microcalcifications on mammograms of an anthropomorphic breast phantom acquired by a direct digital flat-panel detector mammography system (FPM) versus a stereotactic breast biopsy system utilizing CCD (charge-coupled device) technology with either a 1024 or 512 acquisition matrix (1024 CCD and 512 CCD). MATERIALS AND METHODS Randomly distributed silica b...

متن کامل

Patient Dose in Digital versus Conventional Mammography

Abstract. Breast imaging techniques have received renewed attention as a proved means for earlier detection and diagnosis of breast cancer. Due to the extremely high image quality requirements in mammography, all aspects of the imaging process must be optimised. With this purpose new imaging systems have been incorporated. The aim of this paper is to present results of patient dose comparison i...

متن کامل

ارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب مختلف به صورت همزمان از بافت پستان با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی

Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. Materials and methods: A breast phantom was designed and b...

متن کامل

Comparison of contrast detail curves of full field digital with screen film breast phantom images.

In this investigation, we imaged a standard breast phantom and compared the contrast detail curves from a prototype full breast digital mammography system with the corresponding curves for a conventional, analog screen-film system. The full breast digital system exhibited superior contrast detail detectability. The results from this study will be used to plan future clinical evaluations compari...

متن کامل

Evaluation of Doses and Image Quality in Mammography with Screen-Film, CR, and DR Detectors – Application of the ACR Phantom

BACKGROUND Different methods of image quality evaluation are routinely used for analogue and digital mammography systems in Poland. In the present study, image quality for several screen-film (SF), computed radiography (CR), and fully digital (DR) mammography systems was compared directly with the use of the ACR mammography accreditation phantom. MATERIAL/METHODS Image quality and mean glandu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 188 2  شماره 

صفحات  -

تاریخ انتشار 2007