Collagen-Based Bioengineered Substitutes of Donor Corneal Allograft Implantation: Assessment and Hypotheses
نویسندگان
چکیده
To fabricate donor corneal substitutes based on carbodiimide cross-linked porcine collagen, to study their in vitro and in vivo properties, and to elaborate new implantation techniques for the donor corneal collagen-based substitutes, this study had been performed. Bioengineered substitutes of corneal stroma (BSCS) were fabricated by cross-linking porcine type I collagen with 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide and N-hydroxysuccinimide, as previously described. Their refractive indices were measured using an Abbe refractometer. The mechanical properties were evaluated by their ability to tolerate interrupted stitches placed during deep lamellar keratoplasty performed on isolated rabbit eyes. BSCS were then implanted into one cornea of 8 rabbits and were followed-up for 12 months. Our BSCS had refractive indices of 1.24-1.3 (human cornea 1.37-1.38), and tolerated the placement of 12 interrupted stitches well. A new technique, the BSCS "stitchless" implantation, was developed. When implanted into rabbit corneas, BSCS remained stably integrated and clear during the 12 month follow-up. Non-intensive opacities within corneal layers (grade 1.5 on a scale of 0 to 4) were observed in 2/8 eyes during the 1st postoperative week, and in one eye the opacity resolved. In the 2nd eye a fine opacity (grade 1) remained. Light microscopy confirmed the integrity of the implants and the absence of inflammation in corneal stroma. The current data suggest that the BSCS fabricated in the Ukraine by cross-linking collagen is a good alternative to human donor corneas if medical grade porcine collagen is used. In addition, the new "stitchless" technique of BSCS implantation may decrease corneal substitute damage and accelerate its epithelialisation.
منابع مشابه
Innervation of tissue-engineered recombinant human collagen-based corneal substitutes: a comparative in vivo confocal microscopy study.
PURPOSE To compare reinnervation in recombinant human collagen-based corneal substitutes with allografts during a 1-year postimplantation follow-up period in pigs. A retrospective comparison to innervation in porcine collagen-based biosynthetic grafts was also performed. METHODS Pigs received a corneal allograft or a substitute made of either recombinant human type-I or -III collagen. In vivo...
متن کاملControlled Release of Acyclovir Through Bioengineered Corneal Implants with Silica Nanoparticle Carriers
Herpes simplex virus (HSV) infection is the most common cause of corneal blindness in the Western world. Despite effective anti-viral drugs such as acyclovir (ACV), disease recurrence due to the virus establishing latency within the corneal nerves and possibly cells makes treatment very challenging. Furthermore, although effective, current systemic and topical preparations of anti-viral drugs d...
متن کاملBioengineered Corneas Grafted as Alternatives to Human Donor Corneas in Three High-Risk Patients
Corneas with severe pathologies have a high risk of rejection when conventionally grafted with human donor tissues. In this early observational study, we grafted bioengineered corneal implants made from recombinant human collagen and synthetic phosphorylcholine polymer into three patients for whom donor cornea transplantation carried a high risk of transplant failure. These patients suffered fr...
متن کاملTissue engineering technologies: just a quick note about transplantation of bioengineered donor trachea and augmentation cystoplasty by de novo engineered bladder tissue.
Tissue engineering technologies: just a quick note about transplantation of bioengineered donor trachea and augmentation cystoplasty by de novo engineered bladder tissue. C. Alberti Tissue engineering is a multidisciplinary scientific field that aims at manufacturing in vitro biological substitutes to enhance or replace failing human organs. Various types of biodegradable synthetic polymer (pol...
متن کاملTissue-engineered recombinant human collagen-based corneal substitutes for implantation: performance of type I versus type III collagen.
PURPOSE To compare the efficacies of recombinant human collagens types I and III as corneal substitutes for implantation. METHODS Recombinant human collagen (13.7%) type I or III was thoroughly mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The final homogenous solution was either molded into sheets for in vitro studies or into implants with the appropriate...
متن کامل